USER INTERFACE
5-3
Model C303 & C314
User Interface
5
Beater Recovery Display
The Beater Recovery screen only displays when the unit
is in the Beater Recovery mode. If the screen information
for the barrel in the Beater Recovery mode is flashing, it
means the barrel is awaiting Defrost. If it is not flashing,
the barrel is in the Beater Recovery mode. The following
screen shows barrel 2 in the Beater Recovery mode.
Operator Menu Timeout
If the display is left in the operator menu or in any of the
operator menu selections except "Current Conditions,"
the display will return to the system mode screen 60
seconds after the last key press.
The Current Conditions screen will be displayed until
manually changed.
Finding Current Fault Conditions
Faults, when corrected, are cleared from the fault
description screen, with the following exception: BRL
NOT COOLING. This fault requires the operator to press
the OFF (<- -) key (when in the FAULT DESCRIPTION
screen) to clear the fault message and the warning tone.
To see if there is more than one fault in either freezing
cylinder, press the PRIME (+ + +) key. To return to the
OPERATOR MENU, press the MENU SELECT key once.
To return to the Main Screen, use the AUTO (- ->) key to
cycle to MENU ITEM A, then press the MENU SELECT
key.
Screen B is FAULT DESCRIPTION.
The fault
description screen will indicate if there is a fault in one of
the freezing cylinders. Upon correction of the fault, the
warning tone will stop.
Table 5-1
The following are explanations of possible faults and the
display screens. Pressing the +++ key shows the faults
for each freezing cylinder. The freezing cylinders are
referred to as barrel 1 (left barrel), barrel 2 (center
barrel), and barrel 3 (right barrel).
NO FAULT FOUND
No fault conditions are apparent.
BEATER OVERLOAD
Beater motor is out on overload. When this fault
occurs, the affected barrel automatically turns off.
The fault clears when the condition is corrected.
WATER-OK
CO2-OK
AUTO
OK
DEFR
OK
AUTO
OK
Fault Messages
Beater Overload
Beater is out on overload.
Chk Refrig Sys Psi
Out on compressor high
pressure cut-out.
Thermistor Short
Shorted thermistor probe.
Thermistor Open
Open thermistor probe.
H
2
O Pressure Low
Water pressure is low.
CO
2
Pressure Low
CO
2
pressure is low.
Syrup Pressure Low
Syrup is no longer present.
BRL Temp 2 High
Freezing cylinder temperature is
above 120°F (49°C).
BRL Not Cooling
Freezing cylinder is not cooling
after 5-minutes.
No Fault Found
No fault conditions are apparent.
FAULT DESCRIPTION
BARREL 1
NO FAULT FOUND
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
BEATER OVERLOAD
CLR
+ + +
SEL
Содержание C303
Страница 14: ...3 4 SAFETY Model C303 C314 Safety 3 Notes...
Страница 41: ...OPERATING PROCEDURES 6 13 Model C303 C314 Operating Procedures 6...
Страница 43: ...7 2 OPERATOR CHECKLIST Model C303 C314 Operator Checklist 7 Notes...
Страница 47: ...9 2 PARTS REPLACEMENT SCHEDULE Model C303 C314 Parts Replacement Schedule 9 Notes...
Страница 53: ...11 4 LIMITED WARRANTY ON PARTS Model C303 C314 Limited Warranty on Parts 11 Notes...