Weekly Cleaning
(continued)
©McDonald’s Corporation · Australia · Planned Maintenance Manual · Revised November, 2013
Page 4 of 7
Ta
ylor Company Blended Ice Machine Model C029 -
Australia
Weekly
BE 22 W1
21
Start the cleaning cycle.
Press the NEXT key. One at a
time, the cleaning solution
will pump through each
product line.
A bar graph screen will
illustrate the cleaning
progress for each product
line.
22
Place free end of cleaning
tubes into bucket of rinse
water.
Press the NEXT key to start
rinse cycle.
23
Place free end of cleaning
tubes into bucket of KAY-5
Sanitizing solution.
Press the NEXT key to start
the sanitizing cycle.
Sanitizing solution
After the solution stops
pumping through the systems,
it will soak for 60 seconds.
24
Remove cleaning tubes.
Remove the cleaning tubes
from the bucket of sanitizing
solution. Lay the end of the
tubes across the rim of the
bucket.
Keep the drain adaptor
connected to the dispensing
head.
Press the NEXT key to start
the purge cycle.
25
Remove cleaning hose.
Place hose in an empty
bucket.
26
Remove the cleaning tubes
from the inlet fittings.
Place tubes in an empty
bucket.
27
Close CO2 valves for unused
pumps.
Turn the CO2 valves to the
“
up/off
” position to close the
unused pumps.
28
Wipe inside of cabinet door
and inlet fittings.
Wipe the inside of the cabinet
door and the inlet fittings,
using
KAY-5 Sanitizing
solution and a clean, sanitized
towel.
Sanitizing solution