8
Applicability
This Technical Manual applies to a range of Indoor Circuit Breakers (ISM) manufactured by Tavrida Electric.
The following products are covered by this manual:
ISM15_Shell_2(150)
ISM15_Shell_2(210)
ISM15_Shell_2(275)
The model number is shown on the equipment rating plates. If your equipment does not correspond to this number then
this manual is not applicable. Please contact your nearest Tavrida Electric office.
Every care has been taken in preparation of this manual. However, please note that not all the details or variations
in the equipment or process being described can be covered. Neither is it expected to address all contingencies
associated with the installation and operation of this equipment. For any further information please contact your nearest
Tavrida Electric office.
Hazard Statements
This manual contains three types of hazard statements, as follows:
DANGER:
Indicates an imminently hazardous situation that, if not avoided, will result in death or serious
injury.
WARNING:
Indicates a potentially hazardous situation that, if not avoided, could result in death or serious
injury.
CAUTION:
Indicates a potentially hazardous situation that, if not avoided, could result in personal injury
or equipment damage.
Safety Instructions
General hazard statements applying to this equipment are described in this section. Statements relating to specific tasks or
procedures are located throughout this manual.
DANGER:
Contact with hazardous voltage will cause death or severe personal injury. Contact with Recloser
or Control Cubicle terminals should only be undertaken when equipment is isolated from
applicable sources of voltage.
WARNING:
This equipment is not intended to protect human life. Follow all locally approved safety
procedures when installing or operating this equipment. Failure to comply may result in death
or severe personaly injury.
WARNING:
Before working with equipment descriped in this manual carefully read and understand the
contents of this manual. Improper handling, installation, operation or maintenance can result
in death, severe personal injury or demage to equipment.
WARNING:
Power distribution equipment must be properly selected for the intended operation. It must be
installed, used and understand all relevant safety procedures. Failure to comply can result in
death, personal injury or equipment damage.
1
Содержание ISM Shell_2 Series
Страница 1: ...ISM Shell_2 Series Vacuum Circuit Breaker 15kV 29kA 2000A Applications Manual MAN5002239 Revision 4...
Страница 2: ...2...
Страница 6: ...6 1 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 7: ...7 Introduction 1...
Страница 12: ...12 1 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 13: ...13 Receiving Handling and Storage 2...
Страница 19: ...19 Ins tallation 3...
Страница 36: ...36 3 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 37: ...37 Switching and Control Functions 4...
Страница 41: ...41 Commiss ioning Maintenance 5...
Страница 44: ...44 5 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 45: ...45 Signalling 6...
Страница 49: ...49 Special Applications Fast Switching 6...
Страница 53: ...53 Product Line 7...
Страница 55: ...55 Dimens ions and Weights 8...
Страница 61: ...61 8 Mating part with interlocking lever Interlockingshaftwithmountedinterlockinglever...
Страница 62: ...62 Circuit Diagrams 9...
Страница 63: ...63 ISM15_Shell_2 with CM_1501_01 9...
Страница 64: ...64 ISM15_Shell_2 with CM_16_1 9...
Страница 65: ...65 9 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 66: ...66 Technical Data 10...
Страница 71: ...71 10 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 72: ...72 Regulations and Ambient Conditions 11...
Страница 74: ...74 Legal Information 12...
Страница 77: ...77 12 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 79: ...79 Date 12...
Страница 80: ...80 Date 12...
Страница 81: ...81 Date 12...
Страница 82: ...82 THIS PAGE INTENTIONALLY LEFT BLANK...