25
10. LED DESCRIPTION ON THE BOARD
DL4
DL5
DL6
DL7
DL8
DL9
DL2
ABBRE-
VIATIONS
DESCRIPTION
STATE
DL2
Low voltage presence led
ON
DL4
Displays the status of the START input
OFF
DL5
Displays the status of the PEDESTRIAN
OFF
DL6
Displays the status of the PHOTOCELLS
ON
DL7
Displays the status of the STOP input
ON
DL8
Displays the status of the opening limit switch
ON
DL9
Displays the status of the closing limit switch
ON
11. DIP SWITCH DESCRIPTION
1
AUTO LOCK
On
when opening is complete, the closure of the automation is automatic
after the time set during programming has elapsed.
Off
closing requires a manual command.
2
NO REVERSE
On
the automation ignores the closing commands during opening and
the pause time.
Off
it is possible to reverse the movement during closing.
3
2/4 TIMES
On
with the automation functioning, a sequence of opening/closing com-
mands causes the automation to OPEN-CLOSE-OPEN-CLOSE, etc...
Off
in the same conditions, the same sequence of commands causes the
automation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc...
4
NOT USED
On
not used.
Off
not used