![tau D820M Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/tau/d820m/d820m_installation-manual_821502020.webp)
20
4. TECHNICAL DATA
Control unit power supply
230V AC - 50 Hz
Motors output
Three-phase: 230 V AC Single-phase: 230 VAC
Three-phase motors connection
Delta connection
Single-phase motors connection
No capacitor
Motor power
1100W
Operating Temperature
-20°C / + 55 °C
Accessories power supply
12V DC - 500mA (6W)
For higher powers, install an external
transformer
Protections
- motors protected by fuse and electronic
control
- electronically protected circuits
- self-protected switching power supply
- L-C mains filters
5. DESCRIPTION OF THE CONTROL UNIT
P1
8.8
P2
P3
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19
21 20
1.
2.
3.
4.
5.
6.
7.
1. Inputs diagnostic LED
5. Terminals for low voltage connec-
tions
2. Mains voltage presence LED
6. Terminals for high voltage connec-
tions
3. Buttons for programming
7. Terminal for UPS connection
4. Display*