Beginning work

With the machine started:

Always turn the keyswitch to the 0-position and remove the key from the 
machine if you are going to be out of sight of the machine. 
With the machine started:

Cleaning method

Direct method:

Scrubbing and vacuuming in one pass.

Indirect working method:

Apply the cleaning solution (only scrubbing), afterwards scrubbing and 
vacuuming.
The cleaning methods are described in detail in the ”Method Card”. You can 
obtain this from your TASKI partner.

Refilling the solution tank

The rattling noise from the dosing pump indicates that the solution tank is 
empty.

End of operation

Foot pedal

Drain the recovery tank / solution tank

The disposal of the dirty water or the cleaning solution must be carried out in 
accordance with the appropriate national regulations.

Recovery tank

Solution tank

Caution:

Always wear non-slip shoes and appropriate work clothing while 
working with this machine!

• Lower the squeegee.

• Switch on the keyswitch.

The indicators light up briefly.

• Lower the brush unit using the brush unit pedal, refer to page 24.

• First press the cleaning solution button, and 

then the suction unit button.

The indicators light up briefly.

• Choose the volume of solution (+/- button for 

cleaning solution dosing control).

The chosen setting is displayed with green 

lights.

• By gently pressing the speed control in the 

direction of drive, the machine is set in to 
motion.

The tools start to turn and the solution is fed 

through the centre.

If no operations are carried out on the machine, it will switch itself 
off after 5 minutes.

• No manipulations of any kind may be carried out on the brushes.
• the operator must remain within sight of the machine.

• only the squeegee may be cleaned from sucked-in or jammed objects.
• If the J-Fit dosing system has been fitted, the concentrate bag may be 

changed or the settings of the J-Fit machine may be modified.

• the operator may only leave the machine for the purposes of clearing the 

area to be cleaned, but must remain in visual contact with the machine.

Caution:

Do not clean without solution, as it could cause floor damage.

• Stop cleaning.
• Refill the tank, see page 24.

Start

• Stop the flow of solution.

• Drive a few metres so that the tools rotate further for a short time. You will 

avoid dripping by doing this.

Very important when using contact pads!

• To raise the tool, press down the foot pedal and 

lock it in place.

• Drive on a few metres further in order to pick up the remaining dirty water.

• Raise the squeegee.

Allow the suction unit to continue running until 

the rest of the dirty water has been sucked into 

the hose.

• Switch off the suction unit first, and then the 

keyswitch.

Always drain and clean the recovery tank every time you use the 
machine.

If the dirty water is allowed to stand, unpleasant smells and 

deposition of the dirt will take place after a few hours.

• Switch the machine off.

• Take the soiled solution hose from its holder. 

(When emptying the tank, always follow the 
regulations of the detergent manufacturer 
regarding personal protective equipment.)

• Press the neck (1) of the hose together.
• Pull the cover from the hose at the height of the 

handle and slowly lower the end of the hose to 
drain the recovery tank.

 (When emptying the tank, please observe the stipulations of the 
manufacturer of the cleaning agent with regard to personal 
protective equipment.)
Open the blue cap at the height of the handle and then slowly 
lower the end of the hose to drain out the contents.

Start

1

Содержание swingo 1650

Страница 1: ...swingo 1650 1850 V006 12089 52 1043 I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 I15 tr sv ro pt pl no nl it fr fi es en de cz 12089 52 ...

Страница 2: ...tion by a responsible person Children should be supervised to ensure that they do not play with the appliance Do not use these machines in rooms in which explosive and easily inflammable materials such as petrol solvents fuel oil dusts etc are stored or processed The electrical or mechanical components could lead to the ignition of these materials The machines must not be used in rooms that are su...

Страница 3: ...N 60 335 1 EN 60 335 1 A11 EN 60 335 1 A12 EN 60 335 1 A13 EN 60 335 2 72 2009 EN 62 233 EN 55 014 1 2006 EN 55 014 2 A1 EN 61 000 3 2 2006 EN 61 000 3 3 1995 A1 2001 A2 2005 It is ensured through internal measures that series production units conform at all times to the requirements of current EU Directives and relevant standards The signatories act on behalf of company management and with full p...

Страница 4: ...subject batteries to an open flame or heat as there is a danger of explosion from the electolytic gas present in the cells No smoking Danger of chemical burns Caution The battery must always be clean and dry Do not place any metallic objects on the battery The integrated charging unit is only suitable for maintenance free gel traction block batteries Caution Batteries may only be installed or dism...

Страница 5: ...e charged in ventilated rooms only The gas given off could be ignited Switch the machine off using the keyswitch and remove the key Check that the tanks are empty Turn the unlocking device counter clockwise through 90 Use the supplied sheet metal spanner to do this Tank position for charging Plug the external battery charging unit into the charging plug Start the battery charging unit Caution Foll...

Страница 6: ...oot pedal and slowly lower the tool While being lowered the coupling begins to slowly rotate This centres and locks the tool into place Switch the machine off Lay the squeegee under the squeegee holder Position the squeegee so that the squeegee holder is under the towing strap Press the foot pedal down until the squeegee locks into place Plug the suction hoses into the squeegee support Start Start...

Страница 7: ...d may be carried out on the brushes the operator must remain within sight of the machine only the squeegee may be cleaned from sucked in or jammed objects If the J Fit dosing system has been fitted the concentrate bag may be changed or the settings of the J Fit machine may be modified the operator may only leave the machine for the purposes of clearing the area to be cleaned but must remain in vis...

Страница 8: ...residual amount of solution will flow out once the filter cap has been unscrewed Refit the solution filter Switch the machine off using the keyswitch and remove the key To raise the tool press down the foot pedal and lock it in place Press the tool ejector with your foot Clean the tool under running water Switch the machine off Pull the two suction hoses from the squeegee support Press the locking...

Страница 9: ...emove the key The yellow suction filter can be simply removed together with the float quick release connection Clean it with water using a brush let it dry out well Brush the yellow suction filter with a soft brush or remove the fluff with a cloth Malfunction Possible causes Troubleshooting page Machine does not run Maschine switched off Switch on the keyswitch 22 Battery mains unit malfunction di...

Страница 10: ...200 1200 W Noise emission level according to nach EN 60704 1 70 70 dB A Total vibration value of hand arm vibration to ISO 5349 0 5 0 5 m s2 Splash water protection IPX3 IPX3 Protection class without battery charger only CO1650 1 CO1650 1X models III III Electrical protection class with battery charger II II Nr Article CO1650 1 CO1650 1X CO1850 1 CO1850 1X 7515515 Pad drive 33cm X 7515516 Scrubbin...

Отзывы: