Important! Switch the machine off when you:

• e.g. carry out cleaning or maintenance work, or convert the machine to 

another function

• store it in a suitable room in order to avoid any unauthorised use of the unit
• leave it standing without supervision
In addition, you should remove the key from the key-switch and prevent the 

machine rolling away ( for example, by placing a wedge under the machine

).

Store the machine in a dry, dust-free room with a corrosion-free atmosphere.

The temperature must not fall below +10 °C or 35 °C. Low 

temperatures, damp and dust can significantly reduce the service life of the 

electrical components.

Translation of the original EU Declaration of Conformity

We hereby declare that the product described below conforms to the relevant 
safety- and health-related requirements of the appropriate EU Directive in both 
its basic design and construction and in the version marketed by us.
If any modifications are carried out on the product that have not been agreed 
with us, this declaration will no longer be valid.

Applicable EU Directives:

Directive 2006/42/EC

 of the European Parliament and of the Council dated

17th May 2006 regarding machines and for the change to Directive 95/16/EC 
(new wording)

Directive 2004/108/EC

 of the European Parliament and of the Council dated 

15th December 2004 for the harmonisation of the legal regulations of the 
Member States regarding electro-magnetic compatibility and for the annulment 
of Directive 89/336/EEC

Harmonised standards applied:

EN 60 335-1/ EN 60 335-1+A11/ EN 60 335-1+A12/ EN 60 335-1+A13/
EN 60 335-2-72:2009/EN 62 233/
EN 55 014-1: 2006/ EN 55 014-2+A1/EN 61 000-3-2:2006/ 
EN 61 000-3-3:1995+A1:2001+A2:2005
It is ensured through internal measures that series-production units conform at 
all times to the requirements of current EU Directives and relevant standards

The signatories act on behalf of company management and with full power of 
attorney.

Caution:

This machine may not be operated without batteries!

Caution:

The power supply plug of the integrated charger unit must always 
be pulled out of its socket when carrying out any cleaning or 
maintenance work.

Only use the machine on level floors or on gradients of 2% or less.

This symbol on the machine indicates that it is not suitable for use 

on surfaces with greater gradients.

The tank cap must be closed when moving or driving the machine.

 Noise emissions and vibrations:

TASKI machines and units have been designed so that any 
danger to health through the noise emitted or through vibrations 
can be excluded according to the current state of knowledge. 
Refer to the technical information on page 28.

2%

Designation:

Automatic machine for the treatment of floors for 
commercial purposes

Product:

scrubber dryer

Model:

swingo 1650/1850

Model:

CO1650.1

(24 VDC/1200 W)

CO1650.1X (24VDC/1200W) (230-240 VAC/50-60Hz/800W)

CO1850.1

(24 VDC/1200 W)

CO1850.1X (24VDC/1200W) (230-240 VAC/50-60Hz/800W)

Serial number:

Refer to the rating plate on the machine

Trademark:

Manufacturer:

Diversey, 9542 Münchwilen - Switzerland

Responsible for documentation:

Stephan Engler
Diversey Europe B.V. Utrecht
Münchwilen Branch Office
CH-9542 Münchwilen

Münchwilen, dated 26.08.2010

Dipl. Ing. (FH) D.Windmeisser

                   

Dipl. Ing. (FH) P. König

Technical Director  

                      Value Chain Director
                      Floor Care Equipment

Floor Care Equipment 

Содержание swingo 1650

Страница 1: ...swingo 1650 1850 V006 12089 52 1043 I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 I15 tr sv ro pt pl no nl it fr fi es en de cz 12089 52 ...

Страница 2: ...tion by a responsible person Children should be supervised to ensure that they do not play with the appliance Do not use these machines in rooms in which explosive and easily inflammable materials such as petrol solvents fuel oil dusts etc are stored or processed The electrical or mechanical components could lead to the ignition of these materials The machines must not be used in rooms that are su...

Страница 3: ...N 60 335 1 EN 60 335 1 A11 EN 60 335 1 A12 EN 60 335 1 A13 EN 60 335 2 72 2009 EN 62 233 EN 55 014 1 2006 EN 55 014 2 A1 EN 61 000 3 2 2006 EN 61 000 3 3 1995 A1 2001 A2 2005 It is ensured through internal measures that series production units conform at all times to the requirements of current EU Directives and relevant standards The signatories act on behalf of company management and with full p...

Страница 4: ...subject batteries to an open flame or heat as there is a danger of explosion from the electolytic gas present in the cells No smoking Danger of chemical burns Caution The battery must always be clean and dry Do not place any metallic objects on the battery The integrated charging unit is only suitable for maintenance free gel traction block batteries Caution Batteries may only be installed or dism...

Страница 5: ...e charged in ventilated rooms only The gas given off could be ignited Switch the machine off using the keyswitch and remove the key Check that the tanks are empty Turn the unlocking device counter clockwise through 90 Use the supplied sheet metal spanner to do this Tank position for charging Plug the external battery charging unit into the charging plug Start the battery charging unit Caution Foll...

Страница 6: ...oot pedal and slowly lower the tool While being lowered the coupling begins to slowly rotate This centres and locks the tool into place Switch the machine off Lay the squeegee under the squeegee holder Position the squeegee so that the squeegee holder is under the towing strap Press the foot pedal down until the squeegee locks into place Plug the suction hoses into the squeegee support Start Start...

Страница 7: ...d may be carried out on the brushes the operator must remain within sight of the machine only the squeegee may be cleaned from sucked in or jammed objects If the J Fit dosing system has been fitted the concentrate bag may be changed or the settings of the J Fit machine may be modified the operator may only leave the machine for the purposes of clearing the area to be cleaned but must remain in vis...

Страница 8: ...residual amount of solution will flow out once the filter cap has been unscrewed Refit the solution filter Switch the machine off using the keyswitch and remove the key To raise the tool press down the foot pedal and lock it in place Press the tool ejector with your foot Clean the tool under running water Switch the machine off Pull the two suction hoses from the squeegee support Press the locking...

Страница 9: ...emove the key The yellow suction filter can be simply removed together with the float quick release connection Clean it with water using a brush let it dry out well Brush the yellow suction filter with a soft brush or remove the fluff with a cloth Malfunction Possible causes Troubleshooting page Machine does not run Maschine switched off Switch on the keyswitch 22 Battery mains unit malfunction di...

Страница 10: ...200 1200 W Noise emission level according to nach EN 60704 1 70 70 dB A Total vibration value of hand arm vibration to ISO 5349 0 5 0 5 m s2 Splash water protection IPX3 IPX3 Protection class without battery charger only CO1650 1 CO1650 1X models III III Electrical protection class with battery charger II II Nr Article CO1650 1 CO1650 1X CO1850 1 CO1850 1X 7515515 Pad drive 33cm X 7515516 Scrubbin...

Отзывы: