background image

125385D HEPA 700 

Legend Brands, Inc. 

Quick Start Guide

 

HEPA 700 Air Scrubber

 

ELECTRIC SHOCK HAZARD 

The unit must be electrically grounded. Use only on 
GFCI protected receptacles. 

Connect to a properly grounded outlet only. Do not cut 

off the grounding prong. Do not use with an adapter. 

Do not use with extension cords. 

Do not use with damaged cord or plug. If unit is not working as 
it should, has been dropped, damaged, left outdoors, or 
exposed to water, return it to an authorized service center for 
repair. 

Unplug cord from outlet when not in use or when servicing unit. 

ELECTRIC SHOCK HAZARD 

Keep motor and electrical parts dry. 

Do not use outdoors. For indoor use only. 

Do not handle plug or unit with wet hands. 

Do not operate unit in standing water. 

BREATHING HAZARD 

When using the HEPA 700 in a containment area, turn 
off all sources of power to open combustion 
appliances such as fireplaces, boilers, furnaces, water 

heaters and HVAC systems to avoid the risk of backdrafting 
deadly carbon monoxide fumes. 

This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and 
can radiate radio frequency energy, and if not installed and 
used in accordance with the instructions, may cause harmful  

interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following 
measures: 

• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for
help

SPECIAL FEATURES 

Command Hub Technology

 

Integrated Command Hub technology with the free Command 
Center mobile app enables firmware updates and 24/7 
monitoring and control to ensure optimal air filtration. (App 
available soon in Apple and Google Play stores.) 

Ducting options 
Inlet:

 14 in. wire reinforced ducting (purchased separately). 

Outlet:

  14 in.(diameter) layflat or wire reinforced ducting 

(purchased separately) using the provided duct attachment 
ring. Do not exceed a maximum ducting length of 25 ft. / 7.6 m. 

OPERATING INSTRUCTIONS

 

Setup

 

1. Unwrap the cord completely.
2. Place the HEPA 700 with the handle up. Ensure that neither
the inlet nor the outlet are obstructed.
3. Plug into a standard 115V GFCI-protected outlet.

Parts Identification 

Inlet and 
inlet cover. 
Remove 
cover before 
operating. 

Air intake 
ring. Attach 
14 in. semi-
rigid ducting. 

Feet for 
horizontal 
operation & 
stacking. 

Carry handle. 
Folds down when 
not in use.  

Filter cover buckle 
(×4). Release to 
replace filter 
elements. 

Use the hook-and-pile 
fasteners to attach the inlet 
cover here while unit is use. 

115V outlets 
(×2) and 
breaker reset 
switch. 

Filtered air 
outlet. Filter 
retainer ring may 
be used to 
attach 14 in. 
layflat ducting.  

Control panel. 

Отзывы: