5.2.1 HOLSTER MOUNTING
Select proper location for mounting holster, preferably inside a storage compartment. Panel space required will be 6.5” x 8.0” (165 x
203mm). Refer to Figure 5.2.1for hole dimensions. Holster can be used as template.
Fig 5.2.1 Tether Operator Station Holster Hole Dimensions
Material
Use
Material
Use
Thickness
Drill
Thickness
Drill
5/64-3/32
.206
5.2
#5
3/32
.213
5.4
#3
1/8
.213
5.4
#3
1/8
.221
5.6
#2
3/16
.221
5.6
#2
3/16
.228
5.8
#1
Inches
mm
Inches mm
ALUMINUM
STEEL
Hole Size Chart For Self Tapping Screws
Hole Size
Hole Size
5 3/4"
(146 mm)
2 7/8"
(73 mm)
7
1/4"
(184
mm)
5.2.2 RECEPTACLE MOUNTING
Select proper location for mounting receptacle. Receptacle is 1-1/4” x 1-1/4” and 1/2” deep. (32 mm x 32 mm x 13 mm) Allow extra
room behind receptacle for wires. Refer to Figure 5.2.2 for hole dimensions.
Fig 5.2.2
Tether Operator Station
Receptacle Hole Dimensions
Drill (4) .098”
(#40) Holes
7/8”
(22 mm)
7/8”
(22 mm)
25/32”
(20 mm)
HOLE LAYOUT
MOUNT RECEPTACLE WITH
#4 SELF-TAPPING SCREWS.
TIGHTEN SECURELY.
INSTALL
CHAIN CONNECTOR
UNDER SCREW HEAD
Y5310 TETHER RECEPTACLE
Y5320 CLOSURE CAP
5.2.3 ELECTRICAL WIRING
See figure 5.0 for typical connections. The 4-conductor cable from the receptacle needs to be connected to power (red & black) and to
the communication link (blue & white) from the monitor. Refer to Figure 5.1.2 for typical cable preparation.
Drill (3) Pilot Holes
(refer to hole size chart)
Mount Holster With (3)
1/4-20 Self-Tapping Screws.
Tighten Securely.