30
6.2.1.5 JOYSTICK OPERATOR STATION (Y4E-JS)
This operator station is installed in a protected location and allows the monitor to be controlled by a joystick.
6.2.1.6 TOGGLE SWITCH OPERATOR STATION (Y4E-TS)
This operator station allows the monitor to be operated by three toggle switches.
6.2.3 STOW FEATURE
The STOW position needs to be programmed before use. The monitor needs to “find” two (2) hard stops, one for each axis, before the
monitor can move to the STOW position. When programming, the first two commands teach the monitor where to find the hard stops.
This insures that the position is accurate. From that point, the programmer can program the move to the STOW position. During normal
operation, each time the STOW button is pressed, the monitor moves the nozzle to the full straight stream position, moves to each
programmed hard stop, and then moves to the STOW position. While the monitor is performing the STOW feature, pressing any button
will stop the monitor.
6.2.3.1 PROGRAMMING
STOW programming must be initiated within 1 minute of applying power to monitor. After 1 minute, programming access is blocked.
Power must then be cycled to reset 1 minute timer.
and
and
and
and
Press and hold STOW button (~10 seconds) until LED blinks. Release button. LED will continue to blink while in program mode.
Press
release LEFT/RIGHT or UP/DOWN button of axis that will move first to hard stop. LED will blink rapidly when hard stop is
reached.
Press
release LEFT/RIGHT or UP/DOWN button of axis that will move second to hard stop. LED will blink rapidly when hard stop is
reached.
Use LEFT/RIGHT or UP/DOWN buttons to move monitor to first point of stow routine, press
release STOW button. LED will blink
rapidly to acknowledge position.
Repeat until pattern is complete (up to 10 points).
Press
hold STOW button until LED turns off. Release button.
FIRST AXIS TO MOVE:
SECOND AXIS TO MOVE:
MOVE TO STOW POSITION:
6.2.3.2 STOW PROGRAMMING EXAMPLE
- Press
hold STOW button until LED blinks.
- Press
release UP button, monitor will move until hard stop reached. LED blinks rapidly.
- Press
release RIGHT button, monitor will move until hard stop reached. LED blinks rapidly.
- Press LEFT button to move 45 degrees, Press
release STOW button. LED blinks rapidly.
- Press DOWN button to move 90 degrees, Press
release STOW button. LED blinks rapidly.
- Press
hold STOW button until LED turns off.
and
and
and
and
and
and
6.2.2 MASTER OVERRIDE FEATURE (DIP#1)
Any operator station with a communication board can be
reconfigured with the master override feature. These stations
include the Y4E-RP, Y4E-CT-30, Y4E-CT-100, Y4E-TS, or
any inputs connected to an Y4E-COMM.
To enable the
master override feature on an operator station follow these
steps:
1. Remove lid from enclosure.
2. Locate DIP switches on communication board.
3. Slide DIP switch #1 to the ON position.
4. Replace lid. Verify rubber seal is clean and undamaged.
Verify that no wires are caught between lid and box.
Figure 6.2.2
Master Override Setup
ON
CTS
12
3
4
6.2.4 OSCILLATE FEATURE
The OSCILLATE feature allows the user to program a repeating pattern to control the horizontal and vertical axes of the monitor. While
in the OSCILLATE pattern, the monitor will pause while the user changes the stream pattern. Pressing any other button will stop the
OSCILLATE pattern.
A label is supplied with each operator station that can be mounted on or near the station as a reminder of how to program the
OSCILLATE pattern. The OSCILLATE pattern needs to be programmed before use. The pattern will be cleared each time power is
cycled to the monitor.
For fixed monitors, the monitor may be configured to store the program permanently. See section 6.2.4.2.