3.
MAINTENANCE
IOM manual Tapflo Hose pumps
27
Fig. 3.9.3b PT5
–
PT20
Follow steps 3.9.1b and 3.9.2 on the discharge side of
the pump. Additionally, remove the clamp bands
[272] and [273].
Fig. 3.9.4
Start and stop the motor repeatedly in short bursts
(jog run) to extract the hose on the discharge side of
the pump.
NOTE!
During this operation, make sure no one is
standing directly in front of the pump connections as
the hose can come out of the casing at significant
speed and cause severe injury to the operator.
Fig. 3.9.5a PT25
–
PT80
Pre-assemble the flange ring [71/73] using two bolts
on the discharge side of the pump.
Fig. 3.9.5b PT5
–
PT20
Pre-assemble the bracket [170] on the discharge side
of the pump.
272
70
273
170
27
170
71 73
171
171
170
Содержание PT CIP
Страница 46: ...5 DATA IOM manual Tapflo Hose pumps 45...