3.
MAINTENANCE
IOM manual Tapflo Hose pumps
32
3.11.
Shoe shimming
–
PT25
–
PT80
During pump operation as the hose starts to wear, internal leakage inside the hose can occur. In
order to avoid this, additional shims can be added under the shoes in order to increase the
compression of the hose. This is an important procedure, as internal leakage reduces the hose
lifetime and affect the pump flow. The shoe shimming varies based on pump rotation speed,
discharge pressure and liquid viscosity. This operation can be done without complete pump
disassembly, through the sight glass.
NOTE!
Proceed with this procedure only after familiarizing oneself with the instructions at the
beginning of chapter 3.
Maintenance
and all safety instruction in chapter 1.8.
Health and safety
.
Fig. 3.11.1
Start and stop the motor repeatedly in short bursts
(jog run) to position the shoe [92] in front of the sight
glass [41].
Fig. 3.11.2
Disconnect power supply from the motor.
Fig. 3.11.3
Unscrew the sight glass bolts [411] and remove the
sight glass [41] with its gasket [42].
NOTE!
Check condition of the gasket and replace if
necessary.
Fig. 3.11.4
Slightly unscrew the shoe mounting bolt [901].
2
1
11
Содержание PT CIP
Страница 46: ...5 DATA IOM manual Tapflo Hose pumps 45...
Страница 56: ......