3.
MAINTENANCE
IOM manual Tapflo Hose pumps
25
Fig. 3.7.4b
It is also possible to fill the pump with lubricant
directly through the vent plug [331] located on the
top of the pump.
Fig. 3.7.5
Check the condition of the sight glass gasket [42] and
reassemble the sight glass [41] or tighten the vent
plug [331].
3.7.6
Fill the pump casing [11] with appropriate amount of lubricant (see chapter 5.2.
Technical data
for more
information).
The appropriate level of the lubricant inside the pump is:
➢
Below the shaft for PT5
–
PT20;
➢
Below the bottom edge of the sight glass for PT25
–
PT80.