- 17 -
Thermostat Differential (“diF”)
This parameter determines the thermostat switching
differential (or hysteresis), which applies to all thermostat
modes.
Programming:
1.
Press and release the SET button until the “Dif”
parameter is displayed.
2.
Press the UP or DOWN button once to display the current
parameter value. With the current value displayed, use
the UP/DOWN buttons to adjust the parameter to the
desired value.
3.
Hold the SET button to exit programming mode OR press
and release the SET button again to advance to the next
programming parameter
This parameter is only accessible while the Thermostat Configuration
menu (“CC”) is set to “On”.
- 18 -
Units Lock (“UL”)
This parameter can be used to prevent inadvertent changes
to the local temperature display units setting. When this
parameter is set to “On” the thermostat’s temperature units
can not be changed locally.
Programming:
1.
Press and release the SET button until the “UL”
parameter is displayed.
2.
Press the UP or DOWN button once to display the current
parameter value. With the current value displayed, use
the UP/DOWN buttons to toggle this parameter between
“On” and “Off”
3.
Hold the SET button to exit programming mode OR press
and release the SET button again to advance to the next
programming parameter
This parameter is only accessible while the Thermostat Configuration
menu (“CC”) is set to “On”.