background image

47

48

Searching for Remote Units

「 」

mark will appear next to all Remote Unit Names with which 

communication is possible. This function can be useful when selecting 
Remote Units for downloading data or starting recording.

1. 

In the Main Menu, open [ 

SEARCH RMOTE].

2. 

Select the search range from ([All Groups] or [Specify Group]) 

and click to start the search.

Selection

By selecting [All Groups], 

the search will be for Remote Units in all 

groups registered in the RTR-

57

U unit.

By selecting [Specify Group], 

the search will be for Remote Units in the 

specified group.

3. 

After the search has been completed, a list will appear showing 

only the Remote Units with which communication is possible.

A

「 」

mark will appear next to the Remote Unit names with which 

communication is possible.

The

「 」

mark will continue to appear next to Remote Units with which 

communication has become impossible until a new search is conducted.

A search of 

1

 group will take about 

20

 seconds to complete. (The search time 

depends on the number of Remote Units registered in the group.)

By selecting a Remote Unit with which communication is possible and clicking 

on it, you can either download data or get info about that unit.

Searching for Remote Units that have been additionally

 

 

registered in another RTR-

57

U Unit

When selecting the search range, by pressing in on the operation dial, 
it is possible to search for Remote Units that have been added to the 
same Group name in other RTR-

57

U Data Collectors. 

1. 

In the Main Menu, open [ 

SEARCH RMOTE].

�������������

�����

�����

�����

Press in and 
hold

Select the Group 
and press in

 

Searching All Groups

In the [Search in] window, move the 

arrow to [All Groups] and press in on 

the operation dial.

 

Searching by Specific Group

In the [Search in] window, select 

[Specify Group] and continue.In 

the [Call by Group] window, move 

the arrow to the Group you wish to 

search and press in on the operation 

dial.

Ex. of a Search Results List

Remote Units that have been added to 

other RTR-

57

U Data Collectors will 

automatically be shown with [Sr] at the 

head of the name.The three digit number 

shows the Remote Number at the time of 

registration.

�������������

�����

�����

�����

}

Содержание RTR-57U

Страница 1: ...User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit Copyright 2001 2005 T D Corporation All rights reserved 2005 09 16004455040...

Страница 2: ...for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product Some of ou...

Страница 3: ...ns to the unit immediately turn the power OFF and remove the batteries Continued use may cause re or electrocution CAUTIONS This unit is not water resistant If the unit gets dirty wipe it with a clean...

Страница 4: ...ling and cause injury or damage In places exposed to re or heat It may cause damage or a change in shape In places exposed to excessive smoke dirt and dust It may cause damage Wireless Regulations Rad...

Страница 5: ...ta 30 Non Wireless Communication How to Connect for Optical or Optional Communication Cable 33 Recording Conditions Settings 34 Downloading Recorded Data 37 Graph Display 39 Event List Display 41 Othe...

Страница 6: ...at 1 minute the battery life will be about 4 months Easy Data Collection from a Variety of Unit Types Data downloading can be carried out with any RTR 5 Series Unit via wireless communication or by s...

Страница 7: ...ent transmission frequency and ambient temperature This estimate of battery life was based on normal use under normal conditions using a new batteries This is in no way or manner a guarantee of batter...

Страница 8: ...in Move the dial up Move the dial down Moving the dial up and down By moving the dial up or down the arrow will move to allow you to choose the desired item The selected part will be displayed in an e...

Страница 9: ...edure If there is no OK in the setting display but a BACK is displayed adjust the arrow to BACK and press it to complete the setting and take you back to the menu display When carrying out a Remote Un...

Страница 10: ...to save battery power If you wish to continue to use switch the power on again Note If using the monitoring function the Auto Power Off function will not go into effect During communication even by p...

Страница 11: ...tware T D Recorder for Windows US the USB Device Driver will also be copied to your hard disc So even if you do not have the CD ROM but have already installed T D Recorder for Windows you can easily i...

Страница 12: ...to use the device with a USB cable and Windows The USB device driver must be installed for communication via USB between your computer and a RTR 57U Data Collector After installing the USB device driv...

Страница 13: ...ion Window opens close it 4 By connecting a data Collector to the USB cable already connected to your computer the Found New Hardware Wizard will automatically open 5 By clicking the Next button a win...

Страница 14: ...urn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CD ROM drive If t...

Страница 15: ...or a better dirver Recommended and click the Next button to begin installation NEXT button 6 Check Search for the best driver your device Recommended and click the Next button Check NEXT button 7 Chec...

Страница 16: ...r units that have been registered as Remote Units via the accompanying software T D Recorder for Windows US The following operations can be done using Wireless communication Download Recorded Data You...

Страница 17: ...nd change all recording settings such as Recording Mode Recording Interval and Recording Start Date and Time Programmed Start Read Logger Settings The RTR 57U can read and display all settings for the...

Страница 18: ...ing Mode Recording Interval Settings Please extend the antenna when using wireless communication The following settings and changes can be made from the main unit Recording Mode One Time Endless Recor...

Страница 19: ...the RTR 57U are correct before making recording start settings For details see Setting the Date and Time from p 10 programmed start time Immediate Start After having completed the settings adjust the...

Страница 20: ...anual About Reading the Recording Settings Select a Remote Unit and press on Read Settings in the REC SETTINGS Menu After reading the recording settings information for the selected Remote Unit will b...

Страница 21: ...ed when the downloading is completed CAUTION The downloaded data for TR 71U TR 72U will be displayed in the data list under TR 71S TR 72S If the amount of main unit memory is low the downloading of re...

Страница 22: ...l Endless Recording will continue with oldest data continuously overwritten Recording Interval Choose from 15 intervals S 1 2 5 10 15 20 30 seconds M 1 2 5 10 15 20 30 and 60 minutes Some recording in...

Страница 23: ...tings For details see Setting the Date and Time from p10 Immediate Start After having completed the settings adjust the arrow to REC Immediate and press dial to transmit the recording conditions to th...

Страница 24: ...peration dial the display will change to that of a graph If you have set the judgment ON in Set Limits before downloading the result will be displayed when the downloading is completed CAUTION The dow...

Страница 25: ...presently displayed in graph The display can be scrolled with the operation dial or the buttons on the main unit Cursor Bar Fixed Display Cursor position is displayed and measurement information is di...

Страница 26: ...orded Data Reading Shows the reading number of the data at the cursor position Arrows Rising Edge Data Falling Edge Data Both Rising and Falling within 1 second Events within an input voltage range of...

Страница 27: ...computer when setting up the recording start time for the Remote Unit will take precedence over other limit settings Note Settings can also be made via the computer For details see the Help Menu in th...

Страница 28: ...nit you can run a search to find all Remote Units with which communication is possible Those units with which communication is possible will appear with a mark next to them See p 47 for details 3 Clic...

Страница 29: ...nds to complete The search time depends on the number of Remote Units registered in the group By selecting a Remote Unit with which communication is possible and clicking on it you can either download...

Страница 30: ...allow for the necessary amount of communication time If the upper and lower limit settings are activated Result Upper and Lower Limits Ex of a Search Results List For those units with which communica...

Страница 31: ...y Groups The communication time will depend on the number of registered remote units For 250 units registered to 1 group the time will be 54 seconds plus a display time for each unit of 2 seconds View...

Страница 32: ...ete If yes move arrow to and click OK 3 When completed a message will appear Press the operation dial to nish the deletion process Displaying Recorded Data in Graph or Event List 1 In the Main Menu op...

Страница 33: ...due to radio wave interference or other causes communication capability does not meet expected standards To help avoid interference and reduce the chances of poor transmission we suggest that before r...

Страница 34: ...ighter Muting the Operations Buzzer Current Settings Selection 1 In the Main Menu open SET FUNCTIONS and Beep 2 By moving the arrow to OFF and pressing the dial the setting will be completed 3 Move th...

Страница 35: ...Data BACK BACK Display Graph See p 39 Judge See p 44 Select Delete See p 54 Displays the graph for that data View results of judgment After con rmation select OK to nish MONITOR MODE View Current Mea...

Страница 36: ...displayed Record Standby Call by Group Call by Name By Group 2 BACK Upper and Lower Limit Settings See p 43 Backlight See p 57 Set Clock See p 10 Check Memory See p 58 Clear Memory See p 55 Beep See p...

Страница 37: ...after downloading Display Saved Data Graphs Display Highest and Lowest Temperature Set Recording Start for Remote Data Loggers Delete Stored Data one reading all readings Monitor Current Temperature S...

Страница 38: ...to 50 32 to 122 F Humidity Less than 90 RH Without dew condensation Accessories Included Computer Communication Cable USB Cable US 15C Length 60 in 1 5m x 1 AAA Alkaline Batteries LR03 x 2 User s Manu...

Страница 39: ...our company news products upcoming events software and user s guides downloads as well as other support Please stop by and see what we have to offer http www tandd com This is printed on 100 recycled...

Отзывы: