230905-36
TC42_B2 page 5
TOP STANDOFFS
INSTALLATION REQUIREMENTS
The Town & Country Fireplace installation and venting
must conform to the current CAN/CGA-B149 installation
code (in Canada) or the current National Fuel Gas Code,
ANSI Z223.1 (in the USA), and approved per local codes.
Only qualifi ed (licensed or trained) personnel should
install this product.
In the state of Massachusetts, only a licensed Plumber
and Gas Fitter may install this product.
Fig. # 4
Fig. # 5
Examples of Common Locations
TOP STANDOFFS
The top standoffs are shipped loose inside the fi replace and
must be installed on top of the fi replace as shown in
Fig. # 4.
Assembly:
1) Remove the standoffs from inside the fi replace.
2) Position the standoffs in place and secure with screws
provided.
LOCATING THE FIREPLACE
In planning the installation for the fi replace, it is necessary to
determine where the unit is to be installed, location of vent
system and where gas supply piping may be plumbed. Various
installations are possible, such as, into an existing wall, a
corner, a built-in wall or a wall projection (see Fig. #5). Due
to high temperatures, do not locate this fi replace in areas of
high traffi c or near furniture or draperies.
The minimum clearances from the fi replace to combustible
surfaces must be adhered to and are shown on Fig. # 2
and 3.
CAUTION:
When selecting a location, ensure
that there is adequate room on the right or left
hand side of the fi replace for the control box.
SEE FIG #9 FOR
DIME
N
SIO
N
S