page 4 TC42_B2
230905-36
D
E
F
C
B
A
A
9"
D
12"
B
6"
E
6 3/4"
C
3"
F
1 1/2"
**
24"
*
38 1/8"
4"
Minimum Clearances to Combustibles:
Side standoffs ...................... 0 in.
(0 mm)
Back standoffs ..................... 0 in.
(0 mm)
Top standoffs ....................... 0 in.
(0 mm)
Bottom of appliance ............. 0 in.
(0 mm)
Adjacent sidewall ................. 4 in.
(102 mm)
Ceiling to appliance ........... 24 in.
(610 mm)
Mantel to appliance ..........See Figure #2
Maximum
mantel extension ..........See Figure #2
Mantel support ..................... 4 in.
(102 mm)
Vertical vent pipe ........... 1-3/4 in.
(45 mm)
Horizontal vent pipe
Top ............................ 1-3/4 in.
(45 mm)
Sides ........................ 1-3/4 in.
(45 mm)
Bottom ...................... 1-3/4 in.
(45 mm)
Fig. # 3
CEILING
ADJACENT
WA
LL O
R
MANTEL
SUPPORT
MANTEL
UNIT MAY BE RECESSED UP TO
6" WITH NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
COMBUSTIBLE FRAMING
AND FINISH WALL ABOVE
STANDOFFS
MAY USE COMBUSTIBLE
FACING MATERIAL IN
THIS AREA
N O N C O M B U S T I B L E
FINISH MATERIAL
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF SHEET METAL
MA
N
TEL CLEARA
N
CE CHART
REF.
MA
N
TEL
DEPTH
REF.
MA
N
TEL
CLEARA
N
CE
Fig. # 2
N O N - C O M B U S T I B L E
ZONE. DO NOT INSTALL
A N Y C O M B U S T I B L E
MATERIAL, ELECTRICAL
W I R I N G O R G A S
P L U M B I N G I N T H I S
AREA.