TANDBERG MCU
13
Installation
MCU Configuration
The MCU requires some basic configurations before it can be used. It will be necessary to find the IP-address and
program the ISDN-PRI Line numbers.
To do this configuration, follow the instructions below:
1.
Connect the RS232 cable between the MCU and a PC and then switch on the MCU.
2.
Start a terminal program on the PC and configure it to: 9600, 8, 1, None.
3a.
To assign a static IP-address, type ‘ipassign static’ and ‘ipaddress 1 static <IP-address>’.
3b.
To assign an IP Subnetmask, type ‘ipaddress 1 subnetmask <subnetmask>’.
3c.
To assign an IP Gateway address, type ‘ipaddress 1 gateway <gateway IP-address>’.
4.
Restart the MCU.
5.
Start a WEB browser and enter the IP-address of the MCU. Default password: ‘TANDBERG’.
6.
To configure the MCU for ISDN dial in, enter the PRI numbers and dial in number(s). For details, see the ‘PRI
Configuration’ section and the ‘MCU Dial In Numbers’ section under ‘Configure the MCU’.
7.
To configure the MCU for IP dial in, register the MCU to a gatekeeper and enter the H.323 Numbers. For
details, see the ‘H.323 Configuration’ section and the ‘MCU Dial In Numbers’ section under ‘Configure the
MCU’.
TIP
DHCP
ASSIGNED
IP-
ADDRESSES
ARE
SUPPORTED
BY
THE
TANDBERG MCU (
FACTORY
DEFAULT
).