                                                              TXC3150 Conventional Manual Call Point 

Installation & Operation Manual 

                                 
 
 

                                                                    

                                                                                                                                           

Specifications are subject to change w ithout prior notice

 

1.

 

If manual button has a fault after it is used for a long time, first check if manual button is 

damaged or if installation position has not been changed, and then consider other faults of 

manual button.   

2.

 

This product is fire control  product.  Regulations for on-duty and duty shifting system shall be 

carried out. Running records shall be made.  

3.

 

Manual button shall be  tested on alarm function once every six months.   

4.

 

A  special reset tool of this manual button shall be kept and used by a special person. Our 

company will not be responsible for any loss caused by incorrect operation done by non-

authorized person.   

5.

 

It is forbidden to wipe off manual button with dry cloth.   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4050100458-Rev1.0-1017

 

TANDA

 

 

Содержание TXC3150

Страница 1: ...TXC3150 Conventional Manual Call Point Installationand Operation Manual TANDA Development Copyright 2015 All right reserved...

Страница 2: ...are subject to change w ithout prior notice 2 Table of Content 1 General 3 2 Features 3 3 Technical Parameters 3 4 Structure features and operating principle 3 5 Installation and wiring 4 6 Testing 6...

Страница 3: ...ucture is installed easily and reliably 3 Technical Parameters 1 Operating voltage DC24V 12 28V 2 Operating current 1 Normal current 0mA 2 Alarm current 30mA 3 Output capacity rated DC30V 0 1A passive...

Страница 4: ...ndicator of fire alarm is on Fire alarm information is sent to the controller The controller displays fire alarm information 5 Installation and wiring Warning before installation cut off power supply...

Страница 5: ...ut terminal without polarity O1 and O2 cascade connection to the next equipment no polarity or connecting with 5 1K terminal resistance K1 and K2 normally on signal output terminal rated capacity 30V...

Страница 6: ...shall be cut off to avoid unnecessary alarm linkage 2 Press metal dome of manual button Red alarm indicator of manual button shall be on 3 After testing is over reset key is used to reset manual butt...

Страница 7: ...of manual button 2 This product is fire control product Regulations for on duty and duty shifting system shall be carried out Running records shall be made 3 Manual button shall be tested on alarm fu...

Отзывы: