tams elektronik
Multi-Decoder MD-2
English
6.2. Possible settings and default values
CV
Meaning
Default value
Operation
mode
(CV 39)
Operation mode 1
(" turnouts")
Operation mode 2
(" push-buttons")
Operation mode 1
RailCom
(CV 28/CV 29)
Channel 1 and/or 2 on / off
RailCom on / off
RailCom on
Channel 1 and 2 on
Settings for connecting area 1
CV
Meaning
Default value
Servo control
in rest
(CV 65)
Servo control commands are
switched off or sent further.
(to be set individually for each servo)
For all 8 servos: servo
signals are switched
off as soon as the
servo has reached its
rest position.
Servo settings
(CV 40...63f)
left / right stop,
servo velocity
(to be set individually for each servo)
Follow-up time
of servos
(CV 67)
0 ... 25,2 s
(to be set in common for all servos)
500 ms
Teetering
(CV 68/CV 69)
especially for semaphore
signals or railroad crossing
gates: yes/no
(to be set individually for each servo and
each direction of motion)
no
Velocity of
teetering
(CV 70...77)
(to be set individually for each servo and
in common for both directions of motion)
Page 25