6-6 Notice on Pump Operation
1.
During Pump is under process (RUN OR CYCLE)
don’t
try to modify the data.
(Please do it after Pump had stop properly)
▶
In this term of
“
modify data
”
means changing recipe, cycle, CAL value etc. If you modified the
data during pump operation, BUSY screen will be pop-up and it will be not saved.
▶
Screen moving in touch pad is OK.
2.
Dispense Volume set the volume range between 100(1cc) ~ 1000(10cc)
▶
For protect the pump , upper limit alarm set.
3.
Dispense Time It should be bigger than Dispense Volume. It should be smaller than system
recipe step time.
▶
As using the high cp PR , sudden pump operation could have the motor damaged and could
cause the MICRO BUBBLE.
▶
Reload Time => depend on PR cp.
▶
Typically, high cp PR case, adjust 3~8 times reload time than dispense volume.
Ex)
Dispense
Reload
Vol[
300
] Time[500]
Vol[300]
Time[
900
]
▶
This would be main reason of bubble issues. So please watch for this.
4.
Please do not press too hard to any of pump inner joint or others.
5.
Please do not press too hard to Buffer Tank.
900