Useful Function
------------------------------------------------------------------------------------
58
3. It is enable to stop the sequential operation forcibly by OUTPUT OFF during the
sequential operation.
e.g. Once the sequential operation is stopped by OUTPUT button during the output with
the Memory C setting, the OUTPUT will be OFF when any operation time is set for
Memory A, Memory B, Memory C and OUTPUT OFF.
(V)/(A)
(t)
tOff
tC
tB
tA
End of sequential operation
Memory
A
Memory
B
Memory
C
tA:Operating Time with Memory A
tB:Operating Time with Memory B
tC:Operating Time with Memory C
tOFF:Operating Time with OUTPUT OFF
4. It is enable to use slew rate during the sequential operation. The time during the change
of the slew rate will be considered as the sequential operation time.
e.g. 1) The operation in case of achieving the target value by slew rate
(V)/(A)
(t)
tOff
tC
tB
tA
Memory
A
Memory
B
Memory
C
tA:Operating Time with Memory A
tB:Operating Time with Memory B
tC:Operating Time with Memory C
tOFF:Operating Time with OUTPUT OFF