Controlling with External Analog & Contact Signals
------------------------------------------------------------------------------------
147
LEVEL_ALM1 Settings
This handles the operation mode’s status signal as a LEVEL_ALM1 (alarm status).
It can also be used for surveillance as an alarm when switching from constant voltage to constant
current.
Status Signals that can be set in LEVEL1_ALM
CV_STS(Constant Voltage Operation)
CC_STS(Constant Current Operation)
PL_STS(Power Limiter Operation)
Setting Procedures
Press The Function “FUNC.” key.
FUNC. lamp will light.
Settings Item Number (top) and parameters (bottom) will appear
in the Number Display.
Select the Item number with the VOLTAGE dial.
Item 74 : CV_STS
Item 75 : CC_STS
Item 76 : PL_STS
Change the parameters with the CURRENT dial.
0=Not include in LEVEL_ALM
1=Included in LEVEL_ALM
Press the FUNC. key again to finalize settings.
Returns the Number Display to measurement display mode.
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
Содержание ZX-S-1600LAN
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Страница 13: ...About this Product 10 This is blank page...
Страница 63: ...Useful Function 60 This is blank page...
Страница 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Страница 157: ...Special Loads 154 This is blank page...
Страница 199: ...Specifications 196 This is blank page...
Страница 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Страница 201: ...Appendix 198 ZX S 800LN 800LAN...
Страница 202: ...Appendix 199 ZX S 1600LN 1600LAN...