background image

33

Initial position

800 (Height of neck cushion *)

Center of rotation

800 (Height of neck cushion *) 

Center of rotation

Initial position

Shampooing

position

Dimensions

*Height from floor to neck cushion differs slightly from

product to product.

*The illustrations show the spec. of H height and under the floor plumbing.

<Overview Diagram>

Basin:EX-YMSBXYM2

(YUME Basin, Reverse Slide Spec.)

Arm:EX-YMSAF2

(Front Layout, Reverse Slide Spec.)

[Unit: mm]

233

850

50

210

569

1348

218

747

324

988

493

Shampooing

position

210

569

154

930

1175

37°

210

569

102

1093

1024

980

850

233

210

165

569

1348

943

60°

741

50

493

271

*Height from floor to neck cushion differs slightly from

product to product.

Basin:EX-YMSBXYM2

(YUME Basin, Reverse Slide Spec.)

Arm:EX-YMSAR2

(Rear Layout, Reverse Slide Spec.)

Front Layout

Rear Layout

Содержание YUME SWING

Страница 1: ...esin Plated Parts Types of Layout and Standard Positions Preparation How to Use Guiding Clients Care and Maintenance Daily Inspections Before Requesting Repairs Parts Replaced on a Regular Basis Stand...

Страница 2: ...not be conducted by people other than qualified repair technicians Failure to follow this instruction may cause water leakage or abnormal operation leading to injury Safety Precautions Adhere to these...

Страница 3: ...o injury Also coloring dyes on the neck cushion or basin may stain the user s clothes Do not use hot water boiling water of 60 C or higher Using hot water of 60 C or higher may deform or damage the ba...

Страница 4: ...sure to only use this product inside a hairdressing salon Failure to follow this instruction may cause malfunction or damage to the main unit Take care when handling the shower hose When using the bas...

Страница 5: ...gienic conditions Try to clean the hair catcher after each shampoo Do not cover the drain outlet when this product is not going to be used Do not cover the drain outlet with the drain cap towel or sha...

Страница 6: ...brasive compound Do not use an abrasive compound to clean the dual function shower head shower head holder cover etc Use of an abrasive compound sponge with abrasive compound or hard cleaning tools su...

Страница 7: ...product Check the position of the basin and SWING arm before rotating the chair Depends on the fixed position of the chair foot footrest will hit the basin unit resulting in breakage of the chair or...

Страница 8: ...when manufacturing the part and these are not a product failure Position of Warning Labels 8 Caster Cover Dual function shower head Shower Hose Rotation Arm Cover Maintenance Cover Caster Rail Neck Cu...

Страница 9: ...ccessories have been attached properly Caster rail is to prevent floor from getting scratched while the caster of basin unit slides Please note in advance that surface of caster rail may degrade due t...

Страница 10: ...ce when a hard object hits the surface Peeling of the plating may occur from scratches or cracks on the plated surface Check to ensure that there are no scratches cracks or peeling of the plated surfa...

Страница 11: ...eck the Initial Position and Shampooing Position from the illustrations shown below Initial Position Shampooing Position Initial Position Shampooing Position Front Layout Rear Layout Wall Wall Wall Wa...

Страница 12: ...the proper direction 2 Secure the snap buttons of neck cushion on the chair side to the fixing pins of metal fittings 3 While shaping the neck cushion along the metal fittings secure the snap buttons...

Страница 13: ...il they snap into place Attach the sponge to the shower hose Attach the sponge and sponge holder to the shower hose between the shower head holder and the cover Do not remove the cover of holder forci...

Страница 14: ...l stop the water When the basin is not being used turn the tap firmly full right clockwise to turn the water off properly Failure to do this may cause water leakage After shampooing do not cover the d...

Страница 15: ...rsonal injury Caution Caution Depends on the operating environment or conditions the water discharge amount may change significantly when controlling the hot water temperature This phenomena occurs wh...

Страница 16: ...not affect use A small amount of water may flow out but does not affect its convenient use If the decreasing level is significant the gasket of the drain cap may have deteriorated or become worn so r...

Страница 17: ...and chair backrest When sliding the basin unit hold the edge of the basin and slide it Basin unit is locked at initial position and at shampooing position Slight click is felt when the basin is locke...

Страница 18: ...seals attached to the chair base and lower cover 3 Unlock the chair rotation after the client seats on the chair and rotate it to the shampooing position 4 Slide the basin unit to shampooing position...

Страница 19: ...with the basin When reclining the backrest hold the client s head by your hand to avoid client s head to hit the basin When unlocking the chair rotation while the client is laying on the chair to do...

Страница 20: ...separately Product code ES ESST Adjusting the height of ESPOIR Stool 1 While seating on the stool raise the handle and release the lock 2 Adjust it to the desired height 3 Return the handle and lock...

Страница 21: ...of product or personal injury When returning the basin unit return it to the initial position completely Failure to follow this instruction may allow the basin unit to contact to chair etc resulting...

Страница 22: ...e to wipe off any moisture from all parts other than the basin Leaving the product with water drops may result in failure of the product or any contamination will not be removed Caution The drain cap...

Страница 23: ...it is extremely dirty or the surface has deteriorated available at additional cost At the end of work each day wash the neck cushion and head pillows with water wipe them dry with a towel and allow t...

Страница 24: ...water Clean it once a month measure Using a nylon or similar brush remove the dirt such as water stain from the foaming water outlet 4 Re assemble the shower head 1 Insert the foaming water outlet an...

Страница 25: ...with both hands Clean the sponge every day After cleaning the sponge put it in the hose and put it back on the cover Sponge is consumable supply Replace the sponge if degradation causes rubbing sound...

Страница 26: ...hen the basin is filled with water available at an additional cost Basin body Drain cap Gasket Drain cap Drain cap Removing water from filter and cleaning the filter When removing maintenance cover an...

Страница 27: ...filters 4 With cloth cover the floor around the water and hot water supply pipes 5 Close stop valves of the hot water and water supply pipes If there are electrical components such as wires nearby ens...

Страница 28: ...ter leakage 11 Return the maintenance cover to its original position using the Urea screw 1 pce removed at the process 1 10 Return the plumbing cover to its original position using the Urea screw remo...

Страница 29: ...oca tions in total and detach the caster covers When the hair or dirt tangled with caster and it does not move smoothly clean the caster 2 Remove hair and dirt tangled with caster and clean it 3 Retur...

Страница 30: ...temperature setup of the thermostatic control knob proper Is hair clogging the hair catcher Adjust the volume of the water Refer to pages 14 to 15 Adjust the temperature setup of the boiler to the pr...

Страница 31: ...amage to the hose may result in water flooding on or beneath the floor Check valve Replace every three years When the check valve is used continuously for long periods of time there is a possibility t...

Страница 32: ...pressure water pressure 0 1MPa respectively Dual function shower head Shower outlet 10 0L min Low splash foaming mode 6 5 L min Stop valve Single faucet rotary type Operating environment Operating tem...

Страница 33: ...floor plumbing Overview Diagram Basin EX YMSBXYM2 YUME Basin Reverse Slide Spec Arm EX YMSAF2 Front Layout Reverse Slide Spec Unit mm 233 850 50 210 569 1348 218 747 324 988 493 6 Shampooing position...

Страница 34: ...er flows Refer to page 14 to 15 It may cause malfunction of the product or stain may become hard to remove Immediately wipe away the moisture adheres on the parts except inside of the basin There is a...

Страница 35: ...nearest dealer or Takara Belmont directly If water is leaking from the drain hose the drain hose may be worn degraded or damaged Immediately stop using the product and contact the nearest dealer or Ta...

Страница 36: ...1E04ZTB0 36 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan...

Отзывы: