Attach drain hose to installed drain pipe
Caution
• Check that the drain hose is not bent or damaged.
This may affect water flow or damage the drain hose.
• Check that the drain hose clamp is firmly fastened. If it is
not fastened, water may leak or the drain hose may come loose.
• Check that the hose is not in the shape of an Double trap.
An Double trap can adversely affect the flow of drainage water.
If the drain pipe layout causes an Double trap to be formed,
check the installation position of the basin body and
piping dimensions, and make the necessary
adjustments.
Drain hose packing
Drain hose clamp
Drain hose
Fasten
Insert to this line.
Match the center (width) of drain hose
clamp to the indent in the drain hose.
* Firmly insert the drain
hose packing until it hits
the inner stepped section
of the drain hose.
Stepped section
End of drain pipe
Drain hose packing
(1) Install the drain hose packing
to the installed drain pipe.
Installed drain pipe
(2) Pass the drain hose through the
drain hose clamp and attach
the drain hose.
(3) Fasten the drain hose clamp.
1
2
When changing the pipe from NRS, the height (rise) of the drainage
pipe must be adjusted. Detach the joint connected to the drainage
pipe and make the adjustment so that the height (rise) of the drainage
pipe is 110 mm. When changing the pipe from RS1, the pipe can be
used as is. (Height of drainage riser = 90 mm)
Caution
Piping
2
Drainage
Water supply pipe
Hot water supply pipe
Flexible pipe
Packing
Water shutoff valve
9
Before connecting the pipes, remove any waste from the pipes, such
as dust, dirt, sand, or oil. Connect the water shutoff valve to the hot
water/water supply pipes. Then, apply the furnished packing to the
flexible pipe and connect the pipe to the water shutoff valve.
・
Be sure to use the furnished packing. Failure to use the packing
may result in water leaks.
・
Be careful to avoid connecting the pipes for hot water and water
adversely.
< Changing the pipe form RS1/NRS>
A flexible pipe of L = 200 mm is supplied with the product.
When changing the pipe, the length of the flexible pipe may not be
correct. Prepare flexible pipe in the appropriate length for the work
before implementing the replacement or change.
Caution
Installing the Flexible Pipe
Damage
Bend
<excluding AY-P073X,AY-074X>
Floor
S-trap
Drainage
hose
Drainage hose packing
Drainage hose fixture