background image

Attach drain hose to installed drain pipe

Caution

 

• Check that the drain hose is not bent or damaged.

   This may affect water flow or damage the drain hose.

• Check that the drain hose clamp is firmly fastened. If it is

   not fastened, water may leak or the drain hose may come loose.

• Check that the hose is not in the shape of an Double trap. 

   An Double trap can adversely affect the flow of drainage water. 

   If the drain pipe layout causes an Double trap to be formed,

   check the installation position of the basin body and

   piping dimensions, and make the necessary

   adjustments. 

Drain hose packing

Drain hose clamp

Drain hose

Fasten

Insert to this line.

Match the center (width) of drain hose 

clamp to the indent in the drain hose.

* Firmly insert the drain 

hose packing until it hits 

the inner stepped section 

of the drain hose.

Stepped section

End of drain pipe

Drain hose packing

(1) Install the drain hose packing 

to the installed drain pipe.

Installed drain pipe

(2) Pass the drain hose through the 

drain hose clamp and attach 

the drain hose.

(3) Fasten the drain hose clamp.

1

2

When changing the pipe from NRS, the height (rise) of the drainage 

pipe must be adjusted. Detach the joint connected to the drainage 

pipe and make the adjustment so that the height (rise) of the drainage 

pipe is 110 mm. When changing the pipe from RS1, the pipe can be 

used as is. (Height of drainage riser = 90 mm)

Caution

Piping

Drainage

Water supply pipe

Hot water supply pipe

Flexible pipe

Packing

Water shutoff valve

9

Before connecting the pipes, remove any waste from the pipes, such 

as dust, dirt, sand, or oil. Connect the water shutoff valve to the hot 

water/water supply pipes. Then, apply the furnished packing to the 

flexible pipe and connect the pipe to the water shutoff valve.

Be sure to use the furnished packing. Failure to use the packing

    may result in water leaks.

Be careful to avoid connecting the pipes for hot water and water

    adversely.

< Changing the pipe form RS1/NRS>

A flexible pipe of L = 200 mm is supplied with the product. 

When changing the pipe, the length of the flexible pipe may not be

correct. Prepare flexible pipe in the appropriate length for the work 

before implementing the replacement or change.

Caution

Installing the Flexible Pipe

Damage

Bend

<excluding AY-P073X,AY-074X>

Floor

S-trap

Drainage

hose

Drainage hose packing

Drainage hose fixture

Содержание RS III AXIS

Страница 1: ...instructions may be modified and are subject to change without notice Caution The precautions listed here are to ensure that RS can be installed safely and to prevent any danger or risk to the person...

Страница 2: ...siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt sand and oil as these can cause problems After connec...

Страница 3: ...t use non drinkable well water or water that contains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may...

Страница 4: ...g Sheet Pipe packing Chair Main Unit Chair Fixing Screws M8 x 70 Hexagonal head bolt with plain washer spring washer 4 pcs Chair Main Unit Chair Main Unit Chair Side Chair Side The illustration shows...

Страница 5: ...an head machine screw 2 pcs The illustration shows SU COL Double Step Step Fixing Screws M8 x 30 hexagonal head bolt with spring washer 4 pcs U shaped Step Step OR Chair Main Unit The illustration sho...

Страница 6: ...sin Take extra care to ensure not to damage the covers Do not touch the basin body pipes Doing so may cause water leaks The basin is unstable when it is not fixed to the floor Carrying in the Shampoo...

Страница 7: ...Supply Pipe Water Supply Pipe Drainage Pipe RS3 Paper Template Paper Template Request measures to prevent water leakage under the floor and downstairs Be sure to take the necessary precautions to pre...

Страница 8: ...1 Set the lower chair cover so that the claw of the cover will hang on the tentatively fixed truss head screw M5 x 12 8 Claw 3 Fully tighten the truss head screws two locations Truss head tapping scre...

Страница 9: ...hen changing the pipe from NRS the height rise of the drainage pipe must be adjusted Detach the joint connected to the drainage pipe and make the adjustment so that the height rise of the drainage pip...

Страница 10: ...and clean any dirt trapped within the shower head Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not i...

Страница 11: ...p Mounting Washer 2 Brass Hex Nuts 2 Pipe Nipples 2 Mounting Bar Fastening Bolt and Wing Nut Front 1 Preassembled Vacuum Breaker Vacuum Breaker Rubber Gasket Hose Receiver Cap and pipe nipples with th...

Страница 12: ...G 1 4 L800 CONNECT TO THE HOT WATER PIPE AND WATER PIPE INCLUDED VACCUME BREAKER TABLE HOLE PLUG VACCUME BREAKER TABLE CUT THE PLUG AND RUN THE PIPES INTO THE COVER Water supply pipe Hot water supply...

Страница 13: ...n included with the hair trap Attach the drain hose using a hose clamp and apply silicon sealant as require around fitting for a water seal Check carefully for any leaks prior to putting the until int...

Страница 14: ...o unit by aligning the center of the mounting pipes four pieces at the back of the chair and the center of the slotted hole of the chair mounting fixture of the shampoo unit 2 Check that the centers o...

Страница 15: ...iron plate with pan head machine screws M6 x 15 two locations C 5 Tighten the screws for the square pipes which loosened first four locations A 1 Mount the backrest with pan head machine screws three...

Страница 16: ...he latch on the upper side and then hook the two latches on the lower side 2 Mounting of the Chair to the Shampoo Unit 1 Mounting the Armrest Pad Mount the armrest pad with truss head screws four loca...

Страница 17: ...122 111 124 3 6 5 1 4 0 2 2 409 6 Center of Drainage Pipe Rise Dimension Hot water supply 60 mm Water supply 60 mm Drainage 100 mm Basin Operation Angle for Basin Tilt Specification 0 340 462 565 49...

Страница 18: ...cation 353 1193 Seat Slide Width 150 mm Max 6 109 122 111 124 410 3 6 5 1 4 0 2 2 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 Note The dimensions in parentheses show t...

Страница 19: ...109 122 111 124 3 6 5 1 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 567 495 574 446 175 474 49 565 555 176 173 132 129 Note The dimensions in parentheses show the dim...

Страница 20: ...ushion 706 135 138 2 140 1 1625 Double step Specification 1483 U step Specification 259 468 8 8 4 1 4 5 1 5 359 Center of Drainage Pipe Basin Operation Angle 0 340 590 49 175 525 565 555 173 176 129 1...

Страница 21: ...uding neck cushion 659 259 468 1 2 8 4 6 5 382 130 430 Center of Drainage Pipe 0 592 49 175 523 565 554 173 176 129 132 The drawing shows AY S195X AY P069X Basin Operation Angle Height of armrest lead...

Страница 22: ...g neck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY LUXIS AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dim...

Страница 23: ...eck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY ELI AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dimensio...

Страница 24: ...ration Be careful about the installation direction If the cushion is installed in the wrong direction it may contact the backseat Caution Seat side Basin side Execute the installation using the follow...

Страница 25: ...lumber cover and put it on the lumber 3 Place the lumbar cover with the cutout side facing down and align the cover and the corner of the lumbar component Fit the cover over the lumbar part in the se...

Страница 26: ...he pipe form RS1 NRS When changing the pipe from NRS the height of the riser drainage pipe must be adjusted to 110 mm Floor Surface of Tile or Glass Finish The tiles or glass of the floor surface will...

Страница 27: ...27...

Страница 28: ...28 1E02VYA0 NOTE 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Отзывы: