background image

Caution

• When carrying the basin unit, be careful not to hold it at the basin
   part. The basin may move depending on the product
   specifications. Be sure to carry it by holding it at the frame.
• Since the basin unit tends to tumble, be sure to carry the basin
   while maintaining balance.
• Do not carry the basin with the parts on it.
• Never hold the basin unit (ceramic work) at the band end. 
   Failure to follow this instructions may result in breakage of
   the basin.
• Do not hold the main body cover.
   Doing so may cause damage to the main body cover.
• Take care when handling the basin as it is heavy and fragile.
• Do not drag the unit. 
   The foot part of the basin is made of steel, so dragging it may
   damage the floor surface or crack the basin itself.
• The basin may become damaged if scratched by metallic objects
   such as watches or belts. 
   Remove all metallic objects such as watches when carrying the
   basin.
• Take extra care to ensure not to damage the covers.
• Do not touch the basin body pipes. 
   Doing so may cause water leaks.
• The basin is unstable when it is not fixed to the floor. 

Carrying in the Shampoo Unit

Carrying the main body

While supporting the shampoo basin with the hands, remove

    the hexagonal head bolts (phillips head)(M8 x 50) from the

    shampoo unit base (four locations).

When carrying the shampoo unit, be sure to hold it by the frame.

    Do not hold it by the mixer tube located on the side of the basin.

Return the skid to the company after installing the shampoo unit.

    Do not remove the iron plate mounted on the skid.

Detach the lower chair cover and the maintenance cover 

from the shampoo unit.

Detach the shampoo unit from the skid.

Maintenance Cover 

(secure with tape) 

Lower Chair Cover 

(secure with tape)

6

Precaution for carrying the shampoo unit

Place the detached covers in a safe area.

Shampoo Unit

Mixer Tube

Basin

Main Frame

Caution

 

Caution

 

Always have at least two people to carry the main body and hold
the basin when remove the bolt.Otherwise the basin is likely to fall.

Содержание RS III AXIS

Страница 1: ...instructions may be modified and are subject to change without notice Caution The precautions listed here are to ensure that RS can be installed safely and to prevent any danger or risk to the person...

Страница 2: ...siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt sand and oil as these can cause problems After connec...

Страница 3: ...t use non drinkable well water or water that contains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may...

Страница 4: ...g Sheet Pipe packing Chair Main Unit Chair Fixing Screws M8 x 70 Hexagonal head bolt with plain washer spring washer 4 pcs Chair Main Unit Chair Main Unit Chair Side Chair Side The illustration shows...

Страница 5: ...an head machine screw 2 pcs The illustration shows SU COL Double Step Step Fixing Screws M8 x 30 hexagonal head bolt with spring washer 4 pcs U shaped Step Step OR Chair Main Unit The illustration sho...

Страница 6: ...sin Take extra care to ensure not to damage the covers Do not touch the basin body pipes Doing so may cause water leaks The basin is unstable when it is not fixed to the floor Carrying in the Shampoo...

Страница 7: ...Supply Pipe Water Supply Pipe Drainage Pipe RS3 Paper Template Paper Template Request measures to prevent water leakage under the floor and downstairs Be sure to take the necessary precautions to pre...

Страница 8: ...1 Set the lower chair cover so that the claw of the cover will hang on the tentatively fixed truss head screw M5 x 12 8 Claw 3 Fully tighten the truss head screws two locations Truss head tapping scre...

Страница 9: ...hen changing the pipe from NRS the height rise of the drainage pipe must be adjusted Detach the joint connected to the drainage pipe and make the adjustment so that the height rise of the drainage pip...

Страница 10: ...and clean any dirt trapped within the shower head Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not i...

Страница 11: ...p Mounting Washer 2 Brass Hex Nuts 2 Pipe Nipples 2 Mounting Bar Fastening Bolt and Wing Nut Front 1 Preassembled Vacuum Breaker Vacuum Breaker Rubber Gasket Hose Receiver Cap and pipe nipples with th...

Страница 12: ...G 1 4 L800 CONNECT TO THE HOT WATER PIPE AND WATER PIPE INCLUDED VACCUME BREAKER TABLE HOLE PLUG VACCUME BREAKER TABLE CUT THE PLUG AND RUN THE PIPES INTO THE COVER Water supply pipe Hot water supply...

Страница 13: ...n included with the hair trap Attach the drain hose using a hose clamp and apply silicon sealant as require around fitting for a water seal Check carefully for any leaks prior to putting the until int...

Страница 14: ...o unit by aligning the center of the mounting pipes four pieces at the back of the chair and the center of the slotted hole of the chair mounting fixture of the shampoo unit 2 Check that the centers o...

Страница 15: ...iron plate with pan head machine screws M6 x 15 two locations C 5 Tighten the screws for the square pipes which loosened first four locations A 1 Mount the backrest with pan head machine screws three...

Страница 16: ...he latch on the upper side and then hook the two latches on the lower side 2 Mounting of the Chair to the Shampoo Unit 1 Mounting the Armrest Pad Mount the armrest pad with truss head screws four loca...

Страница 17: ...122 111 124 3 6 5 1 4 0 2 2 409 6 Center of Drainage Pipe Rise Dimension Hot water supply 60 mm Water supply 60 mm Drainage 100 mm Basin Operation Angle for Basin Tilt Specification 0 340 462 565 49...

Страница 18: ...cation 353 1193 Seat Slide Width 150 mm Max 6 109 122 111 124 410 3 6 5 1 4 0 2 2 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 Note The dimensions in parentheses show t...

Страница 19: ...109 122 111 124 3 6 5 1 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 567 495 574 446 175 474 49 565 555 176 173 132 129 Note The dimensions in parentheses show the dim...

Страница 20: ...ushion 706 135 138 2 140 1 1625 Double step Specification 1483 U step Specification 259 468 8 8 4 1 4 5 1 5 359 Center of Drainage Pipe Basin Operation Angle 0 340 590 49 175 525 565 555 173 176 129 1...

Страница 21: ...uding neck cushion 659 259 468 1 2 8 4 6 5 382 130 430 Center of Drainage Pipe 0 592 49 175 523 565 554 173 176 129 132 The drawing shows AY S195X AY P069X Basin Operation Angle Height of armrest lead...

Страница 22: ...g neck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY LUXIS AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dim...

Страница 23: ...eck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY ELI AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dimensio...

Страница 24: ...ration Be careful about the installation direction If the cushion is installed in the wrong direction it may contact the backseat Caution Seat side Basin side Execute the installation using the follow...

Страница 25: ...lumber cover and put it on the lumber 3 Place the lumbar cover with the cutout side facing down and align the cover and the corner of the lumbar component Fit the cover over the lumbar part in the se...

Страница 26: ...he pipe form RS1 NRS When changing the pipe from NRS the height of the riser drainage pipe must be adjusted to 110 mm Floor Surface of Tile or Glass Finish The tiles or glass of the floor surface will...

Страница 27: ...27...

Страница 28: ...28 1E02VYA0 NOTE 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Отзывы: