Contents of defect
①
Something wrong with hot water
(
Temperature is unstable
)
②
Hot water
(
high temperature
)
does not come out
③
Water
(
low temperature
)
does not come out
○
Presumed cause
①
There is difference in the water supply or hot-water supply pressure,
or the pressure of hot water supply is higher than the pressure of water supply.
the pressure of water supply
≧
the pressure of hot water supply
[ The difference should be in the range of 0.2Mpa ]
②
Pressure of water supply and hot water supply is high
[ These two should be in the range between 0.1
and
0.4MPa ]
○
How to react
Connect a pressure reducing valve (Optional) on the upper side (mixer side)
of the filtered check valve, then adjust the pressure.
(It is recommended that water supply pressure and hot water supply
pressure become the same pressure
)
Pressure reducing
valve(Optional)
Check valve
with filter
Stop Valve
3
Test water flow
10
●
Detach the aerator core by
using the furnished wrench.
Caution
Always test the water flow to prevent
accidents during use.
Shower outlet flow rate
Filtered check valve
Filter
Remove and clean any dirt
trapped within the filter pipe
Remove and clean any dirt trapped within the shower head
* Test the water flow and inspect the following
items. The hot water may be slightly tainted
at the start of the water flow test,however this
does not indicate any problem.
* For safety reasons, the product's thermostat
is designed so that the hot water does not
exceed 53
℃
.
(if the supply pressure is the same,
water is 20
℃
and hot water is 60
℃
)
(1) Is there no water leaking from the pipe joints?
The pipe joints may come loose during transportation,
so check the joints within the basin thoroughly.
(2) Are the hot water supply and water supply pressures
at the same, stable pressure?
If the pressure is not the same, see "How to adjust faulty
temperature regulation" below.
(3) Can temperature be controlled properly?
(4) Check that the shower outlet flow is sufficient,
by the following as a guide for flow rate.
Aeration shower head : Approximately 8 L/min
Spa shower head (Aeration) : Approximately 8 L/min
(shower) : Approximately 9 L/min
Shower head
Spa shower head
Packing
Aerator core O-ring
Aerator core
Aerator shower head
After the hot water becomes clear during the water flow test,always clean the filter (within the check valve)
and shower head.
Failure to do so can result in insufficient flow rate and faulty temperature regulation.
Cleaning
-
How to adjust faulty temperature regulation
-
Содержание RS III AXIS
Страница 27: ...27...