background image

3

Requirements for Use

 Requirements for hot/cold water supply

 Floor

Make sure that the floor is level.
Make sure that the installation area is flat and free of irregularities.
Use floor panels with high water resistance. 
Raising pipes

In the case where the floor is finished with tiles etc., screwing bolts into the floor 
surface when installing the shampoo unit may cause a crack on the floor surface. 
Change the material of the floor of the installation area to plywood, mortar, etc., 
referring to the product layout drawing and the pattern paper.

* The floor panel must have the strength as shown below.

Waterproofing
• In case of the installation on the second floor or higher, waterproof the floor 

appropriately.

• Drinking water (Non-drinkable well water, or water including sand or rust are not 

approved for use.)

• If the water hardness is 80 ppm or more, treat the water with a water softener in 

order to prevent scale clogging of the equipment.

• Set the pressure within the range from 0.08 MPa to 0.6 MPa (0.8 to 6 kgf/cm

2

).

• When the pressure exceeds 0.2 MPa (2 kgf/cm

2

), select the floor unit "with 

pressure reducing valve" type. 

• The cold water supply pressure must be equal to or higher than the hot water 

supply pressure.

• The difference between the cold water supply pressure and the hot water 

supply pressure must be 0.2 MPa (2 kgf/cm

2

) or less.

• The temperature of hot water supply must be at least 10˚C higher than that of 

hot water from the shower.

Water for use

Pressure of hot/
cold water supply

Temperature of 
hot water supply

Cold/Hot water 
supply

Drain

Wooden floor

Mortar floor

strength of plywood of 30 mm thickness or more

strength of mortar of 50 mm thickness or more

Rc1/2" Floor raising pipe    
Raising height: Hot water supply 80 mm, Cold water supply 110 mm

VU40 Floor raising pipe   Raising height: 90 mm

Special floor 
(stone etc.)

a base with the strength equivalent to the above must be installed at the 
installation position.

Содержание AY-NRS2B-W

Страница 1: ...l to ensure proper installation Leave this manual to the owner after installation completed Owner Keep this manual in a safe place for your future reference NRS Installation Manual Standard EU Spec KA...

Страница 2: ...ted clean the strainer and the shower head Adjust the inclination of the drain pipe to be at least 1 50 for the pipe of 100 or less and at least 1 100 for the pipe of 100 or more Do not mix up the col...

Страница 3: ...r with a water softener in order to prevent scale clogging of the equipment Set the pressure within the range from 0 08 MPa to 0 6 MPa 0 8 to 6 kgf cm2 When the pressure exceeds 0 2 MPa 2 kgf cm2 sele...

Страница 4: ...ootrest and W footrest only M8 x 30 Hex bolt with spring washer x 4 Chair KAZE Chair OTO Chair side Not provided for separate type Shampoo unit side Shampoo unit Stop valve Neck cushion Shampoo unit f...

Страница 5: ...trest and W footrest only M8 x 30 Hex bolt with spring washer x 4 Chair KAZE Chair OTO Chair side Not provided for separate type Shampoo unit side Shampoo unit Stop valve Neck cushion Shampoo unit flo...

Страница 6: ...ure to use the plain washer when tightening the bolt The center of the shampoo unit must be aligned with the center of the chair mount frame The center of the chair mount frame is the notch of the cha...

Страница 7: ...bracket Notes in moving the shampoo unit When moving the shampoo unit hold the shampoo unit at the rear side of the bowl and the mount base Do not hold the mixing pipe in the rear side of the bowl Mo...

Страница 8: ...se a wrench with across flat 12 mm Attaching to the chair mount frame 1 Place the chair on the chair mount frame with aligning the centers of the mount pipes 4 pipes in the back of the chair with the...

Страница 9: ...nstalling the base bracket 2 Installing Shampoo Unit EU spec 1 Fix the base bracket with accessory bolts on the floor at the marked position Rear of the bowl Notes in moving the shampoo unit When movi...

Страница 10: ...bottom of the hole CAUTION Be sure to use the chair mount frame packing when fixing the chair mount frame Be sure to use the plain washer when tightening the bolt The center of the shampoo unit must b...

Страница 11: ...a wrench with across flat 12 mm Attaching to the chair mount frame 1 Place the chair on the chair mount frame with aligning the centers of the mount pipes 4 pipes in the back of the chair with the li...

Страница 12: ...x up the cold water supply pipes and the hot water supply pipes Attaching the drain pipe 1 Insert the drain hose with a bearing sleeve to the raising drain pipe 2 Press the bearing sleeve to the drain...

Страница 13: ...gh the rear cover hole 2 Attaching the front cover Attach the top of the front cover to the unit first and fix it with two screws 3 Base cover Base cover Sectional view Attach Mixing hose Rear cover S...

Страница 14: ...20 440 515 500 Seat height 900 Neck height 295 1180 1340 with U footrest 1480 with W footrest Center of piping 314 365 Raising height Hot water 80 mm Cold water 110 mm Drain 90 mm The dimension in par...

Страница 15: ...furniture shall be at least 650 mm OTO AY OLL AY NRS1 is shown 500 Seat height 670 450 440 515 900 Neck height 1180 1515 with leg rest Center of pipe 314 365 Raising height Hot water 80 mm Cold water...

Страница 16: ...16 Separate type AY NRS2 is shown Raising height 515 440 900 Neck height 314 Center of piping 365 869 Hot water supply 80 mm Cold water supply 110 mm Drain 90 mm...

Страница 17: ...RS1 is shown 572 450 320 440 515 500 Seat height 950 Neck height 295 1200 1360 with U footrest 1500 with W footrest Center of pipe 314 365 Raising height Hot water 80 mm Cold water 110 mm Drain 90 mm...

Страница 18: ...re shall be at least 650 mm OTO AD OLL AY NRS1 is shown 500 Seat height 670 450 440 515 950 Neck height 1200 1535 with leg rest Center of pipe 314 365 Raising height Hot water 80 mm Cold water 110 mm...

Страница 19: ...19 Separate type AY NRS2 is shown Raising height 515 440 950 Neck height 314 Center of piping 365 Hot water 80 mm Cold water 110 mm Drain 90 mm...

Страница 20: ...be sure to check that Attach the neck cushion by following the procedure below After Installation Standard EU spec CAUTION Do not lose the fastener pin Place the neck cushion in the depression of the...

Страница 21: ...hair side Bowl side Standard fixing position 4 points Floor cut out area 100 x 180 Distance to the wall or the furniture etc Min 1200 mm including the space necessary when the leg rest is used Distanc...

Страница 22: ...uding the space necessary when the leg rest is used 192 33 85 35 100 166 243 6 180 160 534 65 343 190 400 140 40 90 191 134 750 Chair side Bowl side Floor cut out area 100 x 180 Chair mount frame floo...

Страница 23: ...23 MEMO...

Страница 24: ...TAKARA BELMONT CORPORA TION Memo 1 1 Higashi shinsaibashi 2 Chome Chuo ku Osaka J apan TEL 06 6213 5945 TELEF AX 06 6212 3680 Pr inted in J apan 0508 05 10 BAEA44A0...

Отзывы: