Bolts to be used:
   Hex bolt x 4
   (with spring washer)

   Marking

1

Lay the accessory pattern paper on the floor as a template at the installation position referring to the raising 
positions of cold/hot water supply pipes and tape the pattern paper.

2

Trace the positions of the shampoo unit base and the screw holes onto the floor.

3

Remove the pattern paper.

1

   Installing the base bracket.

2

Installing Shampoo Unit (EU spec.)

1

Fix the base bracket with accessory bolts on the floor at the marked position.

Rear of the bowl

Notes in moving the shampoo unit

• When moving the shampoo unit, hold the shampoo unit at the rear side of the bowl and the mount base. 

Do not hold the mixing pipe in the rear side of the bowl.

• Move the shampoo unit carefully and deliberately. The bowl is heavy and easy to break. 
• Do not drag the shampoo unit. If dragged, the metal portion of the mount base and the frame may 

damage the floor.

Mount base

Содержание AY-NRS2B-W

Страница 1: ...l to ensure proper installation Leave this manual to the owner after installation completed Owner Keep this manual in a safe place for your future reference NRS Installation Manual Standard EU Spec KA...

Страница 2: ...ted clean the strainer and the shower head Adjust the inclination of the drain pipe to be at least 1 50 for the pipe of 100 or less and at least 1 100 for the pipe of 100 or more Do not mix up the col...

Страница 3: ...r with a water softener in order to prevent scale clogging of the equipment Set the pressure within the range from 0 08 MPa to 0 6 MPa 0 8 to 6 kgf cm2 When the pressure exceeds 0 2 MPa 2 kgf cm2 sele...

Страница 4: ...ootrest and W footrest only M8 x 30 Hex bolt with spring washer x 4 Chair KAZE Chair OTO Chair side Not provided for separate type Shampoo unit side Shampoo unit Stop valve Neck cushion Shampoo unit f...

Страница 5: ...trest and W footrest only M8 x 30 Hex bolt with spring washer x 4 Chair KAZE Chair OTO Chair side Not provided for separate type Shampoo unit side Shampoo unit Stop valve Neck cushion Shampoo unit flo...

Страница 6: ...ure to use the plain washer when tightening the bolt The center of the shampoo unit must be aligned with the center of the chair mount frame The center of the chair mount frame is the notch of the cha...

Страница 7: ...bracket Notes in moving the shampoo unit When moving the shampoo unit hold the shampoo unit at the rear side of the bowl and the mount base Do not hold the mixing pipe in the rear side of the bowl Mo...

Страница 8: ...se a wrench with across flat 12 mm Attaching to the chair mount frame 1 Place the chair on the chair mount frame with aligning the centers of the mount pipes 4 pipes in the back of the chair with the...

Страница 9: ...nstalling the base bracket 2 Installing Shampoo Unit EU spec 1 Fix the base bracket with accessory bolts on the floor at the marked position Rear of the bowl Notes in moving the shampoo unit When movi...

Страница 10: ...bottom of the hole CAUTION Be sure to use the chair mount frame packing when fixing the chair mount frame Be sure to use the plain washer when tightening the bolt The center of the shampoo unit must b...

Страница 11: ...a wrench with across flat 12 mm Attaching to the chair mount frame 1 Place the chair on the chair mount frame with aligning the centers of the mount pipes 4 pipes in the back of the chair with the li...

Страница 12: ...x up the cold water supply pipes and the hot water supply pipes Attaching the drain pipe 1 Insert the drain hose with a bearing sleeve to the raising drain pipe 2 Press the bearing sleeve to the drain...

Страница 13: ...gh the rear cover hole 2 Attaching the front cover Attach the top of the front cover to the unit first and fix it with two screws 3 Base cover Base cover Sectional view Attach Mixing hose Rear cover S...

Страница 14: ...20 440 515 500 Seat height 900 Neck height 295 1180 1340 with U footrest 1480 with W footrest Center of piping 314 365 Raising height Hot water 80 mm Cold water 110 mm Drain 90 mm The dimension in par...

Страница 15: ...furniture shall be at least 650 mm OTO AY OLL AY NRS1 is shown 500 Seat height 670 450 440 515 900 Neck height 1180 1515 with leg rest Center of pipe 314 365 Raising height Hot water 80 mm Cold water...

Страница 16: ...16 Separate type AY NRS2 is shown Raising height 515 440 900 Neck height 314 Center of piping 365 869 Hot water supply 80 mm Cold water supply 110 mm Drain 90 mm...

Страница 17: ...RS1 is shown 572 450 320 440 515 500 Seat height 950 Neck height 295 1200 1360 with U footrest 1500 with W footrest Center of pipe 314 365 Raising height Hot water 80 mm Cold water 110 mm Drain 90 mm...

Страница 18: ...re shall be at least 650 mm OTO AD OLL AY NRS1 is shown 500 Seat height 670 450 440 515 950 Neck height 1200 1535 with leg rest Center of pipe 314 365 Raising height Hot water 80 mm Cold water 110 mm...

Страница 19: ...19 Separate type AY NRS2 is shown Raising height 515 440 950 Neck height 314 Center of piping 365 Hot water 80 mm Cold water 110 mm Drain 90 mm...

Страница 20: ...be sure to check that Attach the neck cushion by following the procedure below After Installation Standard EU spec CAUTION Do not lose the fastener pin Place the neck cushion in the depression of the...

Страница 21: ...hair side Bowl side Standard fixing position 4 points Floor cut out area 100 x 180 Distance to the wall or the furniture etc Min 1200 mm including the space necessary when the leg rest is used Distanc...

Страница 22: ...uding the space necessary when the leg rest is used 192 33 85 35 100 166 243 6 180 160 534 65 343 190 400 140 40 90 191 134 750 Chair side Bowl side Floor cut out area 100 x 180 Chair mount frame floo...

Страница 23: ...23 MEMO...

Страница 24: ...TAKARA BELMONT CORPORA TION Memo 1 1 Higashi shinsaibashi 2 Chome Chuo ku Osaka J apan TEL 06 6213 5945 TELEF AX 06 6212 3680 Pr inted in J apan 0508 05 10 BAEA44A0...

Отзывы: