219
Countermeasure when the machine stopped
Chapter 9
1
2
3
4
5
6
7
8
9
10
11
3B5
Communication error (between CPU card USB
hub), power supply system error of 280 V or 24
V, abnormality of power supply card
Check harness connection between CPU card
and USB hub.
Check and/or replace power supply card.
Check and/or replace DC power supply.
Wrong selection of model at installation of
software
Install the software again.
3B5
MC
Communication error (among CPU card, USB
hub and machine card), USB communication
error due to color change position, 24 V power
supply system error, power supply card error
Check harness connection among CPU card,
USB hub and machine card.
Check and/or replace power supply card.
Check and/or replace 24 V power supply.
3B5
S
Communication error (among CPU card, USB
hub and main shaft driver), USB communication
error due to color change position, 280 V power
supply system error, power supply card error
Check harness connection among CPU card,
USB hub and main shaft driver.
Check and/or replace power supply card.
3B5
X
Communication error (among CPU card, USB
hub and X-axis driver), USB communication error
due to color change position, 280 V power supply
system error, power supply card error
Check harness connection among CPU card,
USB hub and X-axis driver.
Check and/or replace power supply card.
3B5
Y
Communication error (among CPU card, USB
hub and Y-axis driver), USB communication error
due to color change position, 280 V power supply
system error, power supply card error
Check harness connection among CPU card,
USB hub and Y-axis driver.
Check and/or replace power supply card.
3B7
Communication error inside the controller, bad
communication (between CPU card and switch
card)
Turn "OFF/ON" the power.
Check harness connection between CPU card
and switch card.
Replace CPU card or switch card.
3B8 Impossible communication with sequin device III Check the sequin controller card or connection.
3B9
Communication error of up/down color change
driver (Sequin device III only).
Check the sequin driver card (Occurred only
when power is turned ON).
3BA Communication error with sequin device III
Check the sequin controller card or connection
(Occurred only when power is turned ON).
3BC
MC
Communication speed error (machine card)
Check/replace machine card.
3BC
S
Communication speed error (main shaft driver)
Check and/or replace the main shaft driver.
3BC
X
Communication speed error (X-axis driver)
Check/replace the X-axis driver.
3BC
Y
Communication speed error (Y-axis driver)
Check/replace the Y-axis driver.
3BD
MC
Error of ID written to the card. Driver not for
machine card is connected.
Check/replace machine card.
No.
Stop Factor
How to restore
Содержание TFMX-IIC
Страница 2: ...TISM...
Страница 14: ...To search from the menu key...
Страница 39: ...25 1 2 3 4 5 6 7 8 9 10 11 Chapter 3 Screen 1 Screen display 26 2 Message display 31...
Страница 90: ...Embroidery starts 76 Chapter 4...
Страница 158: ...Functions that must be remembered 144 Chapter 5...
Страница 202: ...Design saved in USB memory 188 Chapter 7...
Страница 213: ...To make optional device available for use 199 Chapter 8 1 2 3 4 5 6 7 8 9 10 11 2 To use Bobbin changer YES 6 7 6 7...
Страница 226: ...Functions concerning optional device 212 Chapter 8...
Страница 250: ...236 Inspection Repair Chapter 10...
Страница 266: ...Index...
Страница 267: ...1st Edition June 2004 47th Edition April 2020...
Страница 268: ......