Carrier Wave Identification (CWID)
CWID is a morse identification feature that can be setup using the TB7100
programming application.
7.17.1
Station ID
Can contain a preprogrammed station ID of up to 16 characters in length.
The user may wish to prefix the letters DE before the message, meaning
“from”.
7.17.2
Station ID 2/Message
Can contain a second preprogrammed station ID or a message of up to 130
characters.
7.17.3
Tone Frequency
The Morse tone frequency is programmable from 1Hz to 3000Hz in one
cycle increments. FCC rules state that the frequency shall be 800Hz to
1200Hz.
7.17.4
ID Repeat Time
A programmable repeat time from 1 to 99 minutes. This allows the user to
program how often the ID or message is sent. Setting the output control to
“After PTT” will cause the ID message to be sent following the last
activation of the COR/COS/CTCSS, Inhibit or PTT inputs, provided the
time is met that is programmed in this register.
7.17.5
Speed (Words per Minute)
The speed is programmable from 1 to 99 words per minute (WPM).
7.17.6
Wait Period after Loss of COR/COS/CTCSS Input Before IDing
This register allows from 1 to 99 seconds of delay before the Morse ID will
transmit after COR/COS/CTCSS loss assuming the repeat interval in ID
Repeat Time has expired.
7.17.7
Transmit Key-Up Delay
Programmable key-up delay from 0.0 to 9.9 seconds. This allows for a front
porch delay time before the ID or message is sent. This gives receiving units
Содержание TB7100
Страница 1: ...TB7100 base station Installation and Operation Manual MBB 00001 02 Issue 2 December 2005...
Страница 10: ...10 TB7100 Installation and Operation Manual Tait Electronics Limited December 2005...
Страница 76: ...76 Connections TB7100 Installation and Operation Manual Tait Electronics Limited December 2005...
Страница 126: ...126 Preparation for Operation TB7100 Installation and Operation Manual Tait Electronics Limited December 2005...
Страница 128: ...128 Maintenance Guide TB7100 Installation and Operation Manual Tait Electronics Limited December 2005...
Страница 142: ...142 TB7100 Installation and Operation Manual Tait Electronics Limited December 2005...