20 

 

Reattach the drive cap assembly and piston(s) and the drive assembly. 

 

After  completing  any  valve  maintenance,  press  and  hold  NEXT  and  REGEN  buttons  for  3  seconds  or 

momentarily unplug power source jack (black wire).   This resets the electronics and establishes the service 

piston position.   The display should flash text, software version (e.g.164), and cycle number before resetting 

the valve to the service position. 

 

INJECTOR CAP, SCREEN, INJECTOR PLUG AND INJECTOR 

Unscrew  the  injector  cap  and  lift  off.  Loosen  cap  with  Service  Wrench,  V3193,  or  pliers  if  necessary. 

Attached to the injector cap is a screen. Remove the screen and clean if fouled. 

 

The plug and/or injector can be pried out with a small screwdriver. The plug can be wiped clean. If the plug 

leaks, replace the entire plug. The injector consists of a throat and a nozzle. Replace o-rings. Chemically 

clean the injector with vinegar or sodium bisulfite. The holes can be blown out with air. Both pieces have 

small diameter holes that control the flow rates of water to insure that the proper concentration of regenerant 

is used. Sharp objects, which can score the plastic,  should not be used to clean the injector. Scoring the 

injector or increasing the diameter of the hole could change the operating parameters of the injector. 

  

Two holes are labeled DN and UP. Check for compliance with one of the following: 

a.  for down flow systems, the appropriate size injector is located in the “DN” hole, a plug is in the “UP” 

hole and that the piston is a combination of the main piston and the regenerant piston; 

b.  for backwash only systems, a plug is in the “DN” hole and in the “UP” hole, and  that only the main 

piston exists (the regenerant piston must be removed) and a plug is in the refill flow control position. 

Push the plug(s) and/or injectors firmly in place, replace the screen and hand tighten the injector cap. 

 

REFILL FLOW CONTROL ASSEMBLY OR REFILL PORT PLUG 

To clean or replace the refill flow control, pull out the locking clip and then pull straight up on the elbow. 

Replace the elbow locking clip in the slot so that it is not misplaced. Twist to remove the white flow control 

retainer. The flow control can be removed by prying upward through the side slots of the retainer with a small 

blade flat screwdriver. 

 

Chemically clean the flow control or the white flow control retainer using dilute sodium bisulfite or vinegar. Do 

not use a wire brush. If necessary, replace the flow control, flow control retainer o-ring, or the elbow o-ring. 

 

Reseat the flow control so the rounded end with lettering is visible in the flow control retainer. Reseat the 

white flow control retainer by inserting the retainer into the elbow until the o-ring seats. Remove locking clip, 

insert elbow into valve body to reseat, and insert locking clip. 

 

Do not use Vaseline or other petroleum based oils on o-rings. A silicone lubricant may be used on the elbow 

o-ring or the white retainer. 

 

WATER METER OR METER PLUG 

The  water  meter  wire  does  not  need  to  be  removed  from  the  PC  board  if  the  water  meter  is  only  being 

inspected and cleaned.  To remove the water meter assembly, unscrew the meter cap on the left side of the 

control valve. Pliers may be used to unscrew the nut if necessary. 

 

The water meter assembly is connected to the PC board by a wire. If the entire water meter assembly is to 

be replaced, remove the control valve cover and remove the power source and water meter plugs from the 

PC board. Unlatch the drive assembly and lean it forward. Unthread the water meter wire from the side of the 

drive assembly and through the drive back plate. To reinstall, rethread the water meter wire through the drive 

back plate and the side of the drive assembly. Reattach the drive assembly, water meter, and power plugs. 

 

If there is no water meter wire visible, then a plug should be found in the meter location. 

 

With the nut removed, a slot at the top of the water meter is visible. Twist a flat blade screwdriver in the slot 

between the control valve body and the meter. When the meter is part way out it is easy to remove the water 

meter from the housing. Once the water meter is removed from the control valve body, check that the turbine 

spins freely. If it does not, use two fingers behind the blades to gently pull the turbine from the shaft. 

 

Do not use a wire brush to clean. Wipe with a clean cloth or chemically clean in dilute sodium bisulfite or 

vinegar. The turbine can be immersed in the chemical. Do not immerse electronics. If the turbine is scored or 

damaged or the bearings on the turbine are worn replace the turbine. 

 

Do not lubricate the turbine shaft. The turbine shaft bearings are pre-lubricated. Do not use Vaseline, oils, or 

other lubricants on the o-ring. A silicone lubricant may be used on the black o-ring. 

 

Snap the turbine on the shaft and reinsert the water meter into the side slot. Hand tighten the nut. Do not use 

a wrench. 

  

Содержание T../MA-ANJ series

Страница 1: ...CE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTATIVE MAINTENANCE INSPECTION BY A WATER PROFESSIONAL IS RECOMMENDED TO ENSURE TROUBLE FREE AND CONTINUOUS OPERATION R1 ...

Страница 2: ...n which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times salt dose exchange capacity and gallon capacity regeneration time A salt warning option may also be included THE DEALER 1 Read this page GENERAL INSTRUCTIONS INSTALLER SETTINGS NORMAL OPERATING DISPLAYS and LOW SALT WARNING 2 Complete the CYCLE SEQUENCE SETTINGS 3 ...

Страница 3: ...ough them When moving through any displays or programmings if no buttons are pressed within five minutes the display returns to normal operating displays Any changes made prior to the five minute time out are incorporated To quickly exit any programming Installer Settings etc press CLOCK Any changes made prior to the exit are incorporated If desired two regenerations within 24 hours are possible w...

Страница 4: ...p 5CS Press UP or DOWN until FILL appears Press NEXT to go to Step 6CS Press REGEN to return to previous step Step 6CS Press UP or DOWN until END appears Press NEXT to exit Cycle Sequence Press REGEN to return to previous step SOFTENER SYSTEM SETUP In SOFTENER SYSTEM SETUP you choose the time for the cycles selected in CYCLE SEQUENCE and specifies other operating parameters for the system The uppe...

Страница 5: ...ess as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time The grains capacity for the selected fill time should be confirmed by testing The capacity and hardness levels entered are used to automatically calculate reserve capacity when capacity is set to AUTO...

Страница 6: ...of no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail Press NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Press NEXT until SALT LEVEL MONITOR appears Set Salt LEVEL MONITOR using UP or DOWN If the value is set to OFF no low salt level warning will appear for the user A specific value ALERT will flash on the display when the cal...

Страница 7: ...ion water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolated from the water pressure in the plumbing system Untreated water is supplied to the building See Figure 2 3 Diagnostic Position The inlet handle points toward the control valve and the outlet handle ...

Страница 8: ...ssure relief valve Also be certain that local codes are not violated 4 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to room temperatures under 34 F 49 C 5 The use of resin cleaners in an unvented enclosure is not recommended SERIAL NUMBER Record the serial number on the installer s and customer s records INLET OUTLET PLUMBING Connect ...

Страница 9: ...s allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back siphoned into the conditioner INSTALLER SETTINGS Step 1I Press NEXT and UP simultaneously for 3 seconds Step 2I Hardness Set the amount of hardness in grains of hardness as calcium carbonate per gallon using DOWN or UP The default is 20 with value ranges from 1 to 150 in 1 grain increments ...

Страница 10: ...il the error or alert is reset by the user Press NEXT to exit Installer Display Setting Press REGEN to return to the previous step SET TIME OF DAY Time of day should only need to be set if the battery has been depleted because of extended power outages or when daylight saving time begins or ends If an extended power outage occurs the time of day will flash on and off which indicates the time of da...

Страница 11: ...emaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heav...

Страница 12: ...BACKWASH and the remaining time is counting down Unplug transformer to prevent valve from moving to the next cycle 3 Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly there will be a loss of media 4 When the water is flowing steadily to the drain without the presence of air restore power and momen...

Страница 13: ...12 REPLACEMENT PARTS ...

Страница 14: ...13 REPLACEMENT PARTS ...

Страница 15: ...14 REPLACEMENT PARTS ...

Страница 16: ...15 REPLACEMENT PARTS ...

Страница 17: ...16 REPLACEMENT PARTS ...

Страница 18: ...17 INSTALLATION FITTING ASSEMBLIES ...

Страница 19: ...force on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the upper right corner Pressing to the left helps the drive gears mesh with the drive cap assembly The drive bracket is properly seated when it snaps under the latches on the drive back plate If resistance is felt before latching then notches are not fully engaged the piston rod is not in...

Страница 20: ...nt may be used on black o rings but is not necessary Avoid any type of lubricants including silicone on red or clear lip seals Reinsert the drive cap assembly and piston into the spacer stack assembly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the drive cap bottoms out Excessive force can break the notches molded into t...

Страница 21: ...sing dilute sodium bisulfite or vinegar Do not use a wire brush If necessary replace the flow control flow control retainer o ring or the elbow o ring Reseat the flow control so the rounded end with lettering is visible in the flow control retainer Reseat the white flow control retainer by inserting the retainer into the elbow until the o ring seats Remove locking clip insert elbow into valve body...

Страница 22: ...otating the assembly as you pull it out will enable it to be removed more easily There are three o rings one under the rotor cap one on the rotor stem and one on the rotor seal Replace worn o rings Clean rotor Reinstall rotor Before reinstalling the red arrow handles be sure that o rings on both rotors face to the right when being viewed from the front when the handle pointers are pointing in the ...

Страница 23: ... assy d Piston not in home position d Press NEXT and REGEN or momentarily unplug PC board power e Motor gears not fully engaged Motor wires broken Failed motor e Check motor and wiring f Center drive gear reflector dirty or damaged Missing or broken gear f Replace or clean drive gear s g Drive bracket incorrectly aligned on back plate g Reset drive bracket h PC board is damaged or defective h Repl...