TAG
Heuer Timing
Page 24 / 49
12. Mass Start or Group Start (GRP)
The start time could be provided by a timing impulse or at a pre-defined time
12.1. Start with a timing impulse
(The impulse is provided by a start gate, a photocell or a manual contactor on Input 1)
Select NET TIME (menu – Timing Modes)
Op/a New Run
Input a competitor N° at the start (N° + E1), N°1 in our example.
Give the start by an impulse on INPUT 1 (manual or external)
Select Duplicate (menu)
Input the N° to be duplicated (N°1 in our example)
The N° and the start time are displayed
Duplicate one or several competitor N° started at the same time as N°1
►
Other N° _ _ _ _
: if the competitor N° are not in chronological order (ex 2, 5, 9 etc)
►
N° From _ _ _ _ to _ _ _ _
: if the competitor N° are in a chronological order (eg
from 2 to 10)
WARNING
If you input a lot of competitor numbers in the same group (eg 1 to 150), it could take
several seconds to proceed to the memorisation.
12.2. Start a defined time
The start(s) time(s) must be programmed in the CP 545 after you op/a New Run.
Select
NET
TIME
(menu – Timing Modes)
Op/a New Run
Select
-
Insert Time
and
E1
(Menu)
Input a competitor N° (eg N°1) and th/the start defined time (ex: 12:34:00.000)
If one or more competitor numbers are starting at the same time, select Duplicate and follow
the steps as described above.
WARNING
The defined start times must be referenced with the time-of-day of your
CP 545 (Synchronise).