IMPORTANT
The CP 545 will accept multiple times of the same competitor N° at the start and at the finish. The
times tak/into account in the ranking are the last one’s recorded.
With each new start or finish, the proceeding times are automatically unassigned.
It’s strongly recommended to identify or to cancel these times as soon as possible. This action
will simplify your timekeeping
.
NOTE
This does not apply in the
TRAINING
mode, whereby several runs for a competitor can be memorised
for later analysis.
It is highly recommended to identify or delete all times not identified as soon as possible.
10. Special characters memorized, printed and sent to the PC
–
Wh/a time is unassigned (false start, inter or finish)
Any time modified through a manipulation of start number
+
Any time inserted manually through INSERT TIME (Menu)
=
Any time repeated through DUPLICATE (Menu)
C
Any time cancelled through N° + R + 0 or after a DNF or DSQ
#
Any Start or Finish time of a forerunner (
+ N°)
11. Special function: RESET CP 545
A general
RESET
can be achieved by pushing the mini switch located below the battery cover
RESET
.
For this operation use a small unfolded paper clip or a needle.
WARNING
After a
RESET
, the memory is cleared and all parameters are restored
.
To achieve a
RESET
, the CP 545 batteries should have a good life or alternatively connect the external
power supply. The
RESET
is available with CP 545
ON
or
OFF
.