TAG
Heuer Timing
Page 22 / 49
9. Keyboard shortcuts
These important functions will help you during your timing sessions. They are similar for most of the timing
modes
except
PTB SEQUENTIAL
.
Pay close attention to these
shortcuts and to the
RECALL
function. They allow you to act quickly in case of
errors or unexpected situations.
N°
+
E1
To input or to change a competitor N° before a Start,
or before a Start in
Parallel SEQ
on the blue course,
or before a Finish in
Parallel DIFF
on the blue course.
N°
+
E2
To input or to change a competitor N° before the 1
st
intermediate,
or before a finish in
Parallel SEQ
on the blue course.
N°
+
E3
To input or to change a competitor N° before the 2
nd
intermediate,
or before a finish in
Parallel SEQ
on the red course.
N°
+
E4
To input or to change a competitor N° before the finish,
or before the Start in
Parallel SEQ
on the red course,
or before the finish in
Parallel DIFF
on the red course
+
N°
+
E1
Forunners
numbering at the Start (time calculate but not ranked)
(
E1 – E4
)
To un-identify a competitor already started, passed at an intermediate point or
finished (false Start, false Intermediate, false Finish).
The un-identified (unassigned) times can be recalled with
RECALL
.
(Ex:
R
+
E4
for the finish time) for re-identification with a competitor N° or with
0
(zero) to cancel them (
C
).
+
(
E1 – E4
)
To restore the previous situation (UNDO) if one or several un-assignments were
made by error.
▼
+
(
E1 – E4
)
To disable auto numbering at Start, intermediate or finish.
Start times, intermediate or finish times are th/memorized without competitor
N°. The unassigned times can be recalled with
RECALL
for re-identification.
R
+
(
E1 – E4
)
RECALL
function to recall all memorized times that are unassigned or not
identified, for identification with a competitor N° or with
0
to cancel (
C
).
N°
+
R +
(
E1 – E4
)
Recall of a competitor N° to be modified a cancelled. The time of a competitor N°
can th/be modified or unassigned.
Recall the time for a new identification, or to cancel it with
0
.
▼
+
R
+
(
E1 – E4
)
To disable auto numbering and direct access to
RECALL
for an immediate
identification of the unassigned times received.
F
+
◄┘
Ranking of a single run, or of the addition of two or more runs.
N°
+
R
+
0
To abort
a competitor N° (DNF)
Quick action to cancel the start time of a competitor (
C
).
Warning:
The cancelled times (
C
) with N° +
R
+
0
are memorized but can’t be recalled.
If you made a mistake, it’s necessary to insert the missing Time of Days
manually (via menu)
N°
+
R
+
0
To disqualify
a competitor N° (DSQ).
Quick action to cancel both the start and the finish times of a competitor
Note:
Normally a disqualification is the function of a race jury. However, use this
function if no race jury exists and you desire to remove the athlete from the
ranking due to disqualification.