Pro Pump Controller (ProCon-100)
Rev3.6
2023/07/17
64/70
Copyright
©
2023 by TAEHA CORP. All Rights Reserved
5.9.4
Operation control command
: using COMMAND - S
➔
Shot in current mode command / O
➔
Shot stop command
T
➔
Shot in select mode command / E
➔
Shot complete signal / H
➔
Change channel command
K
➔
Pressure error setting / L
➔
Pressure setting check
Table 18. Operation control command
No.
Command
Action
Send and receive
1
$,S,#
Shot command
ex) $,S,#
① $
: STX (command start)
②
S : Shot in current mode command
③ # :
ETX (command complete)
Host controller
➔
Procon-100
(REQUST)
2
$,S,!,# - Normal
$,S,?,Data,# - Abnormal
Response shot command
ex) $,S,!,# (Normal) // $,S,?,0,# (Busy)
① $ : STX (
command start)
② S :
Shot in current mode command
③ ! :
Normal(shot)
? : Abnormal(not shot)
④
Data
<Abnormal reception status>
- 0 : Busy status
- 1 : Data format error
- 2 : Data input range error
⑤ # :
ETX (command complete)
Procon-100
➔
host controller
(RESPONSE)
3
$,E,#
Shot completion signal transmission (after normal
shot complete)
① $ : STX (
command start)
②
S : Shot complete command
③ # :
ETX (command complete)
Procon-100
➔
host controller
(RESPONSE)
4
$,O,#
Shot stop command
ex) $,O,#
① $ : STX (
command start)
② O :
shot stop command
③ # :
ETX (command complete)
Host controller
➔
Procon-100
(REQUST)