![TAEHA PROCON-100 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/taeha/procon-100/procon-100_operation-manual_4369632061.webp)
Pro Pump Controller (ProCon-100)
Rev3.6
2023/07/17
61/70
Copyright
©
2023 by TAEHA CORP. All Rights Reserved
3
$,R,!,Data,#
Requesting the contents of parameters for
each channel.
ex) $,R,3,#
① $ : STX (
Command start)
②
R : Parameter request transfer
command
③ Data :
Channel number (1~15)
④ # :
ETX (Command complete)
Host controller
➔
Procon-100
(REQUST)
4
$,R,!,Data,# - normal
$,R,?,Data,# - abnormal
Transferring the contents of the requested
channel parameter
ex) $,R,!,3,2,150,150,50,10,50,100,#
① $ : STX (
Command start)
②
R : Parameter request transfer
command
③ ! :
Normal reception complete
? : Abnormal reception
④ Data
<Normal reception condition>
- Channel number : 3 (Channel 3)
- Mode : 2 (MODE 2 /METERING)
- Shot Time : 150 (1.5Sec)
- Metering Value : 150 (15.0mg)
- Shot Speed : 50 (50RPM)
- Suck Back Time : 10 (1.0Sec)
- Suck Back Speed : 50 (50rpm)
- Compensation : 100 (100%)
<Abnormal reception condition>
- 0 : Busy status
- 1 : Data format error
- 2 : Data input range error
⑤ # :
ETX (Command complete)
Procon-100
➔
host contoller
(RESPONSE)