Tador CD-200 Скачать руководство пользователя страница 7

            

 

CD-200-SET

 Installation Guide 

  

7

 

  

Operation   

 
Calling at the door 

Press the Bell 

֠

֠

֠

֠

. A short tune will be sound,

 

wait for vocal answer. If authorized, the lock will 

buzz for 3 seconds, and you may enter. 

Opening the lock using the keyboard 

Enter the access code confirm with 

*

The lock will be open for the time value it was programmed. 
Each key stroke is followed by a Beep sound, entering a false code or invalid pressing is 
followed by a “Beeeep” sound sequence. 
When exit the secured area press the bypass pushbutton, the lock will be open for the 
programmed time value (could be set to different value than entering). 

 

Answering a call from the gate using one of the telephones 

When a ringing call is heard from the telephones (in a different rhythm than usual), pick up 

the handset. 

If the ringing was : long Beep followed by a short one – the call is from the main door. 

If the ringing was : short Beep followed by a long one – the call is from the secondary door. 

Speak with the visitor. After one minute the call will be disconnected. 

To open the door – press “

1

”. The lock will be released for 3 seconds. 

To disconnect the call with out opening the door - press “

0

”.  

 

Answering a call from the gate while speaking in the telephone 

If a signal is heard in the handset while speaking in it, answer the call by pressing on “

7

” and 

then “

*

”. The telephone call will be held on with background music. 

Speak with the visitor, identify from which gate the call is coming from. 

To open the door – press “

1

”. The telephone conversation will be back to you. 

To return to the telephone call with out opening the door - press “

0

”.  

 

Calling the panel from the house 

Pick up the handset. Press on “

7

” and then “

*

”. To switch between the doors press “

*

”. 

Speak with the visitor. 

To open the door – press “

1

”. The lock will be released for 3 seconds. And the call will be 

disconnected. 

To disconnect the call with out opening the door - press “

0

”.  

 

 
 
 

Содержание CD-200

Страница 1: ... Conn Codeline CD 200 Surface Mount Codeline CD 200 AV Flush Mount Adapter AR 200 Surface Mount Tador Technologies LTD Amagshimim 18 Qiriat Matalon Petach Tikva 49170 Israel Phone 972 3 9226351 Fax 972 3 9210461 www tador net 2000 Tador Technologies Ltd All rights reserved AR 200 ...

Страница 2: ...1 9 seconds Controlling electric or magnetic lock Normally open or normally closed Dimensions CD 200 Panel surface mount installation only 6 3 16 H x 3 12 16 W x 1 12 16 D CD 200 AV Panel Face plate 8 5 H x 4 63 W x 1 25 D Back box 7 5 H x 4 W x 1 25 D Installation the adapter Setting the jumpers Before installing the adapter the adapter s jumpers should be set according to the installation and th...

Страница 3: ...n to the wires already connected from the adapter The opening time from pushbutton can be programmed and be different than the keyboard s time Installing the CD 200 According to the door lock type 3 pins Jumper J3 should be set Desirable RLY state when entering valid code Jumper J3 Close circuit Normally open for electric lock Jumper on 2 left pins default state Open circuit Normally close for mag...

Страница 4: ...ves the manufacturer site adjusted Sometimes because of the location opened or closed space acoustical problems occur If the panel s speaker sound level is too high or low gently rotate the panel s internal SP potentiometer If the sound level of the panel in the telephones is too high or low gently rotate the panel s internal MIC potentiometer AR 200 Adapter Electrical Drawing ...

Страница 5: ... the following sequence should be entered memory cell number 2 digits access code 2 6 digits confirm with To finish press You can add more access codes in cells 01 70 in the same way to use the access code press the access code followed by For example storing the code 9124 in cell number 01 Press 123456 01 then 9124 confirm with To finish press Changing the programming code Enter the programming c...

Страница 6: ... 1 digit Confirm with To finish press Remark when setting the keyboard opening time a value to the bypass pushbutton must be set also even if not installed For example setting the keyboard opening time to 5 sec And pushbutton to 7 sec Press 123456 00 then 5 then 7 confirm with To finish press Summery and examples Programming option execution default Entering programming code 123456 Changing progra...

Страница 7: ...ll is from the main door If the ringing was short Beep followed by a long one the call is from the secondary door Speak with the visitor After one minute the call will be disconnected To open the door press 1 The lock will be released for 3 seconds To disconnect the call with out opening the door press 0 Answering a call from the gate while speaking in the telephone If a signal is heard in the han...

Отзывы: