6

 

  

now the following sequence should be entered: memory cell number to cancel(2 digits), and 

֠

֠

֠

֠

 

֠

֠

֠

֠

 confirm with *. 

For example: canceling the code stored in cell number 01: 
press the following sequence:  

123456 

*

,  

01

 *. 

To finish press: 

֠

֠

֠

֠

 
Setting opening times values 

A different opening time value can be set to opening via the keyboard and via the optional 
bypass pushbutton. 
The times values are from 1 second till 9 seconds. 
Enter the programming code: if not changed is: 123456 *, the green led will blink. 
now the following sequence should be entered: memory cell number 00, opening time via 
keyboard (1 digit) followed by opening time via bypass pushbutton (1 digit). Confirm with *. 
To finish press: 

֠

֠

֠

֠

Remark: when setting the keyboard opening time, a value to the bypass pushbutton must be 
set also, even if not installed. 
For example setting the keyboard opening time to 5 sec. And pushbutton to 7 sec. 
Press: 123456 

*

,

00

 then 

5 then 7

 

confirm with 

*

.  To finish press: 

֠

֠

֠

֠

 
Summery and examples 

Programming option 

execution 

default 

Entering programming code 

 123456  

*

 

 

Changing programming code 
For example: new code 777456 

Enter programming code, 

*

 

 99-777456  

*

 

֠

֠

֠

֠

 

123456 

Storing a new access code 
For example: cell number 01 
access code: 2040 

Enter programming code, 

*

 

 01-2040 

*

 

֠

֠

֠

֠

 

All the cells are empty  
(not 0) 

Canceling access code stored in 
cell number 01 

Enter programming code, 

*

 

 01 

*

 

֠

֠

֠

֠

 

 

Setting opening time from 
keyboard to 2 seconds and from 
bypass pushbutton to 5 seconds 

Enter programming code, 

 00-25 

*

 

֠

֠

֠

֠

 

3 seconds from 
keyboard, 
3 seconds from bypass 
pushbutton 

Содержание CD-200

Страница 1: ... Conn Codeline CD 200 Surface Mount Codeline CD 200 AV Flush Mount Adapter AR 200 Surface Mount Tador Technologies LTD Amagshimim 18 Qiriat Matalon Petach Tikva 49170 Israel Phone 972 3 9226351 Fax 972 3 9210461 www tador net 2000 Tador Technologies Ltd All rights reserved AR 200 ...

Страница 2: ...1 9 seconds Controlling electric or magnetic lock Normally open or normally closed Dimensions CD 200 Panel surface mount installation only 6 3 16 H x 3 12 16 W x 1 12 16 D CD 200 AV Panel Face plate 8 5 H x 4 63 W x 1 25 D Back box 7 5 H x 4 W x 1 25 D Installation the adapter Setting the jumpers Before installing the adapter the adapter s jumpers should be set according to the installation and th...

Страница 3: ...n to the wires already connected from the adapter The opening time from pushbutton can be programmed and be different than the keyboard s time Installing the CD 200 According to the door lock type 3 pins Jumper J3 should be set Desirable RLY state when entering valid code Jumper J3 Close circuit Normally open for electric lock Jumper on 2 left pins default state Open circuit Normally close for mag...

Страница 4: ...ves the manufacturer site adjusted Sometimes because of the location opened or closed space acoustical problems occur If the panel s speaker sound level is too high or low gently rotate the panel s internal SP potentiometer If the sound level of the panel in the telephones is too high or low gently rotate the panel s internal MIC potentiometer AR 200 Adapter Electrical Drawing ...

Страница 5: ... the following sequence should be entered memory cell number 2 digits access code 2 6 digits confirm with To finish press You can add more access codes in cells 01 70 in the same way to use the access code press the access code followed by For example storing the code 9124 in cell number 01 Press 123456 01 then 9124 confirm with To finish press Changing the programming code Enter the programming c...

Страница 6: ... 1 digit Confirm with To finish press Remark when setting the keyboard opening time a value to the bypass pushbutton must be set also even if not installed For example setting the keyboard opening time to 5 sec And pushbutton to 7 sec Press 123456 00 then 5 then 7 confirm with To finish press Summery and examples Programming option execution default Entering programming code 123456 Changing progra...

Страница 7: ...ll is from the main door If the ringing was short Beep followed by a long one the call is from the secondary door Speak with the visitor After one minute the call will be disconnected To open the door press 1 The lock will be released for 3 seconds To disconnect the call with out opening the door press 0 Answering a call from the gate while speaking in the telephone If a signal is heard in the han...

Отзывы: