Tador CD-200 Скачать руководство пользователя страница 5

            

 

CD-200-SET

 Installation Guide 

  

5

 

  

 

Programming: 

100 memory cells up to 6 digits long each one, available. 
Cell 00 is used for door opening times values storage.  
Cell 99 is used for programming code value storage. 
The cells from 01 to cell 70 are used for different access codes values storage. 
Code length is minimum 2 digits and ,maximum 8 digits. (programming code is a 6 digits 
only, and recommended access code is 4 digits) 
Programming code, access codes and opening times values are programmable via the 
keyboard. 
Programming mode: in order to store new access code, set opening times or changing the 
programming code, you should enter to the Programming mode. 
After clicking the valid programming code (manufacturer code if not changed is 

123456 

confirm with*) the green led is blinking, now you can do the required programming as 
described in the following examples. When finished you can enter more access codes or exit 
this mode to the regular state by pressing 

֠

֠

֠

֠

Each key stroke is followed by a Beep sound, entering a false code or invalid pressing is 
followed by a “Beeeep” sound sequence. Entering a valid sequence to memory cell is followed 
by a long terraced sound. 

 
Examples: 
Storing a new access code 

Enter the programming code: if not changed is: 123456 confirm with *, the green led will 
blink. 
now the following sequence should be entered: memory cell number (2 digits), access code 
(2-6 digits), confirm with *. To finish press: 

֠

֠

֠

֠

You can add more access codes in cells 01-70 in the same way. 

-

 

to use the access code: press the access code followed by *. 

For example storing the code 9124 in cell number:01. 
Press: 123456 

*

01

 then 

9124

  confirm with 

*

.   

To finish press: 

֠

֠

֠

֠

 
Changing the programming code 

Enter the programming code: if not changed is: 123456 confirm with *, the green led will 
blink. 
now the following sequence should be entered: memory cell number 99 , new programming 
code (must be 6 digits), then confirm with *. 
Now you can add access codes in cells 01-70 as described or exit. 
To finish press: 

֠

֠

֠

֠

For example changing the programming code to: 649731. 
Press: 123456 

*

99

 then 

649731

 

,confirm with 

*

.   

To finish press: 

֠

֠

֠

֠

You should keep this code because this is the only way to enter the programming 
mode! 
 
Back to Initial status – default 

Using an internal jumper the initial programming code can be restored. The access codes will 
not be changed.

  

Turn the power off. Dismount the panel. Install a jumper on upper 2 pins labeled: 

DEF

 turn 

on the power, a long terraced sound voiced for confirmation. 
Turn off the power and move the jumper to 2 pins below. Reinstall the panel. 
The CD-200 returns to normal condition. The Programming code now is: 123456 *. 

 
Canceling an access code 

A particular access code could be cancel if its memory cell location is known. 
Enter the programming code: if not changed is: 123456 *, the green led will blink. 

Содержание CD-200

Страница 1: ... Conn Codeline CD 200 Surface Mount Codeline CD 200 AV Flush Mount Adapter AR 200 Surface Mount Tador Technologies LTD Amagshimim 18 Qiriat Matalon Petach Tikva 49170 Israel Phone 972 3 9226351 Fax 972 3 9210461 www tador net 2000 Tador Technologies Ltd All rights reserved AR 200 ...

Страница 2: ...1 9 seconds Controlling electric or magnetic lock Normally open or normally closed Dimensions CD 200 Panel surface mount installation only 6 3 16 H x 3 12 16 W x 1 12 16 D CD 200 AV Panel Face plate 8 5 H x 4 63 W x 1 25 D Back box 7 5 H x 4 W x 1 25 D Installation the adapter Setting the jumpers Before installing the adapter the adapter s jumpers should be set according to the installation and th...

Страница 3: ...n to the wires already connected from the adapter The opening time from pushbutton can be programmed and be different than the keyboard s time Installing the CD 200 According to the door lock type 3 pins Jumper J3 should be set Desirable RLY state when entering valid code Jumper J3 Close circuit Normally open for electric lock Jumper on 2 left pins default state Open circuit Normally close for mag...

Страница 4: ...ves the manufacturer site adjusted Sometimes because of the location opened or closed space acoustical problems occur If the panel s speaker sound level is too high or low gently rotate the panel s internal SP potentiometer If the sound level of the panel in the telephones is too high or low gently rotate the panel s internal MIC potentiometer AR 200 Adapter Electrical Drawing ...

Страница 5: ... the following sequence should be entered memory cell number 2 digits access code 2 6 digits confirm with To finish press You can add more access codes in cells 01 70 in the same way to use the access code press the access code followed by For example storing the code 9124 in cell number 01 Press 123456 01 then 9124 confirm with To finish press Changing the programming code Enter the programming c...

Страница 6: ... 1 digit Confirm with To finish press Remark when setting the keyboard opening time a value to the bypass pushbutton must be set also even if not installed For example setting the keyboard opening time to 5 sec And pushbutton to 7 sec Press 123456 00 then 5 then 7 confirm with To finish press Summery and examples Programming option execution default Entering programming code 123456 Changing progra...

Страница 7: ...ll is from the main door If the ringing was short Beep followed by a long one the call is from the secondary door Speak with the visitor After one minute the call will be disconnected To open the door press 1 The lock will be released for 3 seconds To disconnect the call with out opening the door press 0 Answering a call from the gate while speaking in the telephone If a signal is heard in the han...

Отзывы: