V1 12/2021 | Art. Nr. 216221 | EA-Nr. 1374
Installation and operating instructions
taconova.com | 14
After setting, confirm again with „OK“. Now you can spend the mi-
nutes set the switch-off time. Confirm again with „OK“. The day of
the week and will now flash again You can make the settings for the
other days of the week. After about 10 seconds the settings are ad-
opted without pressing a button. The pump automatically switches
to the normal operation and now works with the set times. You can
change the times change at any time as described. To exit smart
mode, press Menu button „ “ again for 3 seconds. This switches the
pump from Smart mode to Timer mode.
7.4 Temperature setting
The stop temperature and the start temperature of the pump can be
changed. The stop temperature is at least 2 ° C higher than the start
temperature, and the temperature setting range is 20 - 60 ° C.
Setting start temperature, stop temperature:
Press the menu button „ “ at the bottom left to enter the selecti-
on mode. To press Then press the „+“ „-“ buttons until „Co.Tem“ is
displayed, then press „OK“ to enter the Temperature setting mode.
In the temperature setting mode, you can press Use the „OK“ button
to switch between the start and stop temperatures.
Pressing the „+“ „-“ buttons changes the start or stop temperature,
this symbol „ “ means that the start temperature is set when this
symbol „ “ is displayed means this that the stop temperature is
set. After a waiting time of approx. 7 seconds, the pump switches to
normal operation and the Pump works in the set temperature range.
TACOFLOW2 PURE PLUS