V1 12/2021 | Art. Nr. 216221 | EA-Nr. 1374
Installation and operating instructions
taconova.com | 12
Press the left menu button to enter the selection mode. In the lower
part of the display flashes to indicate the current standard mode
„mode“, press the button „OK“ to go directly to the temperature con-
trol mode. When the word „fashion“ ends flashing and permanently
lit, the setting is complete. The temperature range can be changed
as described in chapter 7.4.
7.2 Timer mode (temperature control with adjustable timer function)
When the timer mode is switched on, the „timer“ symbol lights up.
For every day of the week three switch-on and switch-off times can
be set. The pump is switched on at the set time, if the temperature
of the tap water is lower than the set start temperature, and runs
until the temperature of the tap water reaches the set stop tempe-
rature.
To set the time periods, proceed as follows:
Press the left menu button „ “ to enter the selection mode, press
the „+“ „-“ - button to enter the timer mode („Timing“ is then dis-
played). To press The OK button. The timer symbol stops flashing
and the day of the week flashes. Choose Use the „+“ „-“ buttons to
select the day of the week for which you want to set the times. To
confirm You this with OK. The number “1” flashes after “Ti per”. This
is the first program slot for the Times can be set. You can now press
the „+“ „-“ buttons two more Select further program positions. Con-
firm the program location you want to change with OK. Now use the
„+“ „-“ buttons to set the hours for the switch-on time. Press it this
with OK. The minutes are now flashing and can be changed. Confirm
with OK. Now the hours for the switch-off time flash. After setting,
confirm again with „OK“.
TACOFLOW2 PURE PLUS