7
MALFUNCTION
POSSIBLE CAUSE
ELIMINATION
1. The pump is not
discharging any liquid,
the motor is not
running.
1.
2.
3.
4.
5.
6.
No current.
Thermal motor protection feature has triggered.
The capacitor is defective.
The motor shaft is jamming.
The electronic pump control is defective.
The anti-dry-running feature is activated (red
“Error”
indicator lights up).
1.
2.
3.
4.
5.
6.
Please use a device complying with GS (German
technical supervisory authority) to check for the
presence of voltage (safety information to be
observed!). Please verify the correct position of the
plug.
Separate the pump from the electrical mains, allow
the system to cool down, eliminate cause.
Please contact the customer service department.
Check the cause; eliminate the reason for the
jamming of the pump.
Please contact the customer service department.
Refer to section 2.2 and 2.3 and chapter 9.3.
“
Cutting out in the case of dry running or absence of
water
”
2. The motor is running,
but the pump is not
discharging any liquid.
1.
2.
3.
4.
The pump housing is not filled with liquid.
Air penetrates into the intake line.
Suction height and/or discharge height too great.
The difference in height between the electronic
pump control and the point of withdrawal, limited
to max. 15 m by the preset value, has been
exceeded.
1.
2.
a)
b)
c)
d)
3.
4.
Fill the pump housing with liquid (please refer to
”Putting into operation” section).
Check to make sure that:
the connection points of the intake line are tight;
the inlet opening of the intake line including the
check valve (non-return valve) are immersed into
the liquids being discharged;
the check valve (non-return valve) with the filter is
tight and not jammed;
no siphons (i.e. permanently liquid-filled loops),
kinks, counter-slopes or narrow spots are present
along the intake lines.
Change the arrangement of the installation so that
the suction height and/or discharge height will not
exceed the max. value.
The switch-on pressure of the electronic pump
control is to be increased. This must only be done
by a qualified provider of plumber or electrician
services.
3. The pump stops after a
short time of operation
because the thermal
motor protection
feature has triggered.
1.
2.
3.
4.
The electrical supply does not correspond to the
information given on the type plate.
Pump or intake line are blocked by solids.
Liquid is too viscous.
Temperature of liquid or environment is too high.
1.
2.
3.
4.
Please use a device complying with GS (German
technical supervisory authority) to check the voltage
of the lines of the connection cord (safety
information to be observed!).
Remove possible congestion.
Pump may not be suitable for this liquid. If feasible,
the liquid should be thinned.
Make sure that the temperature of the liquid being
pumped and the environment do not exceed the
max. admissible values.
4. The pump stops
because the anti-dry-
running feature is
activated (red “Error”
indicator lights up).
1.
Refer to section 2.2. + 2.3.
1.
Refer to section 2.2. + 2.3.
5. The pump cuts in and
out too frequently.
1.
2.
Permanent loss of very small quantities of liquid
(e.g. dripping water tap, leaking hoses or
connecting elements).
Electronic pump control is defective.
1.
2.
Eliminate leakages.
Please contact the customer service department.
6. The pump does not cut
out.
1.
2.
Permanent loss of large quantities of liquid.
Electronic pump control is defective.
1.
2.
Eliminate leakages.
Please contact the customer service department.
7. The pump does not
reach the desired
pressure.
1.
2.
Refer to section 2.2.
Worn pump wheel.
1.
2.
Refer to section 2.2.
Please contact the customer service department.
16
Содержание HWA 3600 INOX
Страница 53: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 3 7 5 8 5 9 6 10 7 11 8 12 9 13 9 1 RCD FI 30 mA 50...
Страница 55: ...3 4 5 1 17 18 1 2 19 5 3 6 6 1 40 C 5 C Teflon Teflon 52...
Страница 56: ...4 6 2 2 1 HA 4 m 25 3 4 0 3 m HI 6 3 11 5 6 7 6 4 T I P 30943 4 13 6 5 FI 30mA DIN VDE 0100 702 0100 738 53...
Страница 57: ...5 7 FI 30 mA DIN VDE 0100 739 3 x 1 0 mm VDE 8 54...
Страница 58: ...6 8 8 9 2 T I P HWA 7 230V AC Error T I P HWA 9 9 1 9 2 9 3 55...
Страница 59: ...7 9 4 1 5 bar 10 10 service 1 any liquid the motor is not running 1 2 3 4 5 6 1 2 3 4 5 6 GS 2 2 2 3 9 3 56...
Страница 61: ...9 1 2 3 12 www tip pumpen de 13 PDF e mail service tip pumpen de 2012 19 EU 58...
Страница 94: ...1 T I P 1 1 2 2 3 3 4 3 5 3 6 3 7 4 8 5 9 6 10 6 11 8 12 9 13 9 1 RCD FI 30 mA 91...
Страница 98: ...5 Fl 30 mA DIN VDE 0100 739 3 x 1 0 mm VDE 8 8 8 9 2 T I P HWA 95...
Страница 99: ...6 7 230V Error Start Pump e T I P HWA 9 9 1 9 2 9 3 Error Start Pump 9 4 1 5 10 96...
Страница 100: ...7 10 1 1 2 3 4 5 6 Error 1 2 3 4 5 6 GS On 2 2 2 3 9 3 2 1 2 3 4 2 15 1 2 a 3 4 3 1 2 3 4 1 2 3 4 GS 97...
Страница 101: ...8 4 Error 1 2 2 2 3 1 2 2 2 3 5 1 2 1 2 6 1 2 1 2 7 1 2 2 2 1 2 2 2 11 vis major a 1 2 3 98...
Страница 102: ...9 12 www tip pumpen de 13 PDF service tip pumpen de EU EU 2012 19 EU 99...
Страница 134: ...1 T I P 1 1 2 2 3 3 4 3 5 3 6 3 7 5 8 5 9 6 10 6 11 8 12 9 13 9 1 RCD 30 131...
Страница 136: ...3 3 T I P 4 5 Fig 1 17 18 1 2 19 5 3 6 6 1 40 C 5 C 133...
Страница 137: ...4 6 2 2 1 HA 4 25 3 4 0 3 HI 6 3 11 5 6 7 6 4 T I P 30943 13 6 5 FI 30 mA DIN VDE 0100 702 und 0100 738 2 134...
Страница 138: ...5 7 FI 30 DIN VDE 0100 739 3 x 1 0 VDE 8 8 9 8 2 T I P HWA 135...
Страница 139: ...6 7 230 Error Start Pump T I P HWA 9 9 1 9 2 9 3 Error Start Pump 9 4 10 136...
Страница 140: ...7 10 1 1 2 3 4 5 6 Error 1 2 3 4 5 6 2 2 2 3 9 3 2 1 2 3 4 15 1 2 a b c d 3 4 3 1 2 3 4 1 2 3 4 137...
Страница 141: ...8 4 Error 1 2 2 2 3 1 2 2 2 3 5 1 2 1 2 2 2 6 1 2 1 2 7 1 2 2 2 1 2 2 2 11 1 2 3 138...
Страница 142: ...9 12 www tip pumpen de 13 PDF service tip pumpen de 2012 19 EU 139...
Страница 143: ...1 T I P 1 1 2 2 3 3 4 3 5 3 6 3 7 4 8 5 9 6 10 6 11 7 12 8 13 8 1 30 140...
Страница 145: ...3 3 T I P 4 5 Fig 1 17 18 1 2 19 5 3 6 6 1 5 C 40 C 142...
Страница 146: ...4 6 2 2 1 HA 4 25 3 4 0 3 HI 6 3 11 5 6 7 6 4 T I P 30943 13 6 5 FI 30 m DIN VDE 0100 702 und 0100 738 2 7 143...
Страница 147: ...5 FI 30 DIN VDE 0100 739 3 x 1 0 VDE 8 8 9 8 2 T I P HWA 144...
Страница 148: ...6 7 230 Error Start Pump T I P HWA 9 9 1 9 2 9 3 Error Start Pump 9 4 1 5 10 145...
Страница 149: ...7 10 1 1 2 3 4 5 6 Error 1 2 3 4 5 6 2 2 2 3 9 3 2 1 2 3 1 2 a b c d 3 3 1 2 3 4 1 2 3 4 4 1 2 2 2 1 2 2 2 11 146...
Страница 150: ...8 1 2 3 12 www tip pumpen de 13 PDF service tip pumpen de 2012 19 EU 147...