INSTRUCTION MANUAL
44
In this screen you can check the values of the counters and reset the piece counter. Total
piece counter cannot be reset.
6.4.1.2 PROGRAMMING- SCREEN
You have to be logged in at least in level 1 to edit the programs. You can save 5000
programs. You cannot execute programs in this screen.
- You can set the program name by pushing the name- field on the top of the field.
- You can browse through programs with arrows on the top of the screen or you can give
the program number to the top left corner on the screen.
- By pushing the mm/inch- field you can change the unit.
- On “Back pos.”- field is shown the position where the work cycle starts. After that the
frame slides to start position of the forming. You can change the value by pushing the
field.
¨
NOTE! The value of the “Back pos.” has to be 60mm larger than the value
of the “Start pos.”. For example if the “Start pos.”= 25mm the “Back pos.”
has to be at least 25mm + 60mm= 85mm.
- On “Start pos.”- field is shown the position where the tool starts to bend the pipe end.
You can change the value by pushing the field. Recommended value for this is 23mm +
the buffer plate thickness.
- On “Buffer plate”- field is shown the thickness of buffer plate. (See buffer plates in page
31 ) You can change the value by pushing the field.
- With “Delete recipe”
- button you can delete the current recipe.
- With arrow
- button you can return to Menu- screen.