![T-Drill F-400 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/t-drill/f-400/f-400_instruction-manual_3075621038.webp)
INSTRUCTION MANUAL
38
1. Before switching the flanging machine on, the work supervising personnel and the
employees shall carefully acquaint them with the manual, the structure of the machine
and it’s functioning. Memorise the location of each operating switch and the function the
switch regulates.
Make sure that:
- There are no unauthorised persons in vicinity of the machine.
- All service doors and safety guards are in place.
- Gas throttle and closing valves are closed (only in hot version).
- Cams are in correct position for flanging.
- Make sure that the forming pin is suitable for the work.
2. Start the hydraulic motor (the hydraulic pump begins to run) with button 7 and press
heating stop push button 9 to energize the air valve (latter only in hot version).
3. Set the switches to point the desired work cycle.
For example cold flanging
Normal flanging.
Cold forming. (If you have heating unit)
1 phase flanging.
4. To pressurize the hydraulic system close the clamp with switch 13
.Make sure that
the clamp jaw can move freely (i.e. no foreign obstacles are between jaws.)
L
DANGER! Before closing the clamping jaws, make sure they can move
freely - the jaws may crush your hands!
L
DANGER! Do not loosen the upper clamps tightening screw when
clamps are open. The clamp might fall down and crush your fingers!
5. Drive the moving carriage to back position. with switches 13
and 14
. Note
that the switches have to be used simultaneously.
6. Turn the forming pin (tool head) to the starting position. Switches 13
and 15
simultaneously.
7. Slide must be in position where the adjustment screws are in upper (abtrubtly 120°)
sector. If not, rotate spindle to correct position. (Press the drum rotation push button
briefly until drum is positioned to limit)
8. Open the clamping jaw. Switch 13
9. Stop the motor by pressing power off -button. Button 8
10. Select the proper clamps. With clamp size 139.7 mm and smaller, the clamp adapters
has to be used. The adapters are installed same way as clamps, and the small clamps are
installed to adapters.