![SZKTDZ KT-LCD4 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/szktdz/kt-lcd4/kt-lcd4_user-manual_1423882034.webp)
ELECTRIC BICYCLE METER KT
—
LCD4 Product User Manual
- 32 -
Enter C8 parameter setting interface after C7 parameter setting is finished, press
button (
SW
), C8 parameter column flashes.
C8 parameter setting interface
C8 is motor operating temperature display setting, the setting range is 0 or 1,
press
button
(UP)
or
button
(DOWN)
for selection.
C8 parameter definition table
:
C8 value
Motor operating temperature
0
Function off
1
Function on
Please Note
:
The motor operating temperature display requires installing temperature
sensor in the motor, output temperature detection signal simultaneously.
After finishing C8 parameter setting, press
button (
SW
) to save the current
value and then press
button (
DOWN
) to enter C9 parameter setting interface.
○
C9 Startup Password Setting
Enter C9 parameter setting interface after C8 parameter setting is finished, press
button (
SW