![SZKTDZ KT-LCD4 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/szktdz/kt-lcd4/kt-lcd4_user-manual_1423882022.webp)
ELECTRIC BICYCLE METER KT
—
LCD4 Product User Manual
- 20 -
meter for more than 1 minute, and then the meter will automatically return to display
1, and the original set parameter will be saved.
After finishing P1 parameter setting, press
button to save the current set values
and press
button
(DOWN)
to enter P2 parameter setting interface.
○
P2 Wheel Speed Pulse Signal Setting
Enter P2 parameter setting interface,then
press
button
P2 parameter column
flashes.
P2 parameter setting interface
P2 is wheel speed pulse signal setting, if wheel generated 1 pulse signal by a
revolution, P2 should be set as1. If wheel generated 6 pulse signals by a revolution, P2
should be set as 6. If users didn’t configure the pulse signal system, and then P2 parameter
setting can be 0. The setting range of P2 should be between 0-6, hold
button (
UP
)
shortly or
button
(DOWN)
for selection.
Under P2 parameter setting interface, if there’s no button operation on the meter
for more than 1 minute, and then the meter will automatically return to display 1,
and the original set parameter will be saved.