![SZKTDZ KT-LCD4 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/szktdz/kt-lcd4/kt-lcd4_user-manual_1423882031.webp)
ELECTRIC BICYCLE METER KT
—
LCD4 Product User Manual
- 29 -
C5 parameter setting interface
C5 is controller maximum operating current adjustment setting (tiny-adjustment of
limit current value), the default value is 10, setting range is 0-10, press
button (
UP
)
or
button
(DOWN)
for selection.
C5 parameter definition table
:
C5 value
Maximum current value(A)
00
Three level slow start/ Maximum current value
01
Two level slow start/ Maximum current value
02
One level slow start/ Maximum current value
03
Maximum current value
÷
2.00
04
Maximum current value
÷
1.50
05
Maximum current value
÷
1.33
06
Maximum current value
÷
1.25
07
Maximum current value
÷
1.20
08
Maximum current value
÷
1.15
09
Maximum current value
÷
1.10
10
Maximum current value