ection 2  

  T

erminating the wiring

Connecting the system input

Connect the cable marked with the zone 
name to the system input of the speaker 
following the wiring shown below:

System input

Main connection from hub

Connecting the keypad

Note:

 For IR equipped speakers; the 

connection of the KPM1 keypad is 
optional.

Keypad

Connects to keypad

Connect the keypad cable to the keypad 
connection (note only 4 wires are used).

Connecting the feed to the passive 
speaker

Left speaker

Connect the cable marked Left speaker to 
the left-channel speaker output. 

Note:

 The doubling up of each coloured 

pair of CAT5/6 wires

Spare cable

The spare cable can be used for a number 
of purposes including the connection of 
a dedicated power supply, a centralised 
local input and as a spare if another cable 
is found to be damaged.

Note:

 No connections are normally made 

to the power supply input of the speaker 
when used as a main zone. This is because 
power is normally relayed via the system 
input cable.

2.5 Connections required 

for additional 
functionality

Local input

Depending on the wiring scheme, 
provision might have been made for a 
local input. This is one that is exclusive to 
the zone. A local input maybe connected 
locally in the room, or it may be connected 
centrally alongside the hub. Either way, 
the local connection must be made at this 
point. 

Please also note that all eight wires are 
connected as this allows an IRM module 
to be connected alongside a SIM module 
to facilitate IR control of the local source.

If only a single SIM is being fi tted with 
no IRM then ensure that the 4 unused 
cables are cut back and/or insulated at the 
module end of the cable:

Local Audio

From SIM

Local IR

From IRM

Содержание Multi-room system

Страница 1: ...MULTI ROOM SYSTEM Systemline Modular Installation Guide MULTI ROOM SYSTEM I n s t a l l a t i o n G u i d e...

Страница 2: ...ded on the CD Rom accompanying the Systemline Modular Read all the instructions before connecting or operating the Systemline Modular Pay particular attention to the safety information Keep this manua...

Страница 3: ...ple active speakers are used to distribute sound over a large area usually with synchronised volume control An expanded zone can also be configured with two or more areas of independent volume control...

Страница 4: ...nt 13 Directly connected music source 13 Remotely connected music source 13 2 13 Connecting the PIM power input module for sub zones 14 2 14 Wiring for a single zone system no hub 14 3 Testing the sys...

Страница 5: ...please ensure that you refer to the wiring schedule or equivalent document that details exactly how the home has been pre wired A wiring schematic and parts list should also be available We recommend...

Страница 6: ...Guide and reprinted below Under stairs cupboard With new construction the wall socket point for the connection of the hi fi system would be located alongside the FM aerial socket in the lounge or fam...

Страница 7: ...Remember also that for some small rooms such as ensuite bathrooms only a single mono speaker may have been provided for Clearance Drill a small diameter hole in the ceiling at the marked point and ch...

Страница 8: ...iling The flange of the ceiling speaker bezel will cover any slight imperfections around the hole itself 2 4 Connecting the active right channel ceiling speaker Important Take the utmost care to ensur...

Страница 9: ...local input and as a spare if another cable is found to be damaged Note No connections are normally made to the power supply input of the speaker when used as a main zone This is because power is norm...

Страница 10: ...eo setting to mono In this mode the speaker will mix both stereo channels into mono sound reproduction If a passive speaker is connected that too will operate in mono mode Disabling the LED display on...

Страница 11: ...in place 2 3 4 1 Continue to tighten the four mounting screws in rotation until the speaker is held firmly flush against the ceiling Do not over tighten as you may crack the mounting tabs or strip th...

Страница 12: ...ypad to this mode Make sure that the keypad is operating normally put the zone into standby red LED ON Depress the O and VOL keys on the keypad simultaneously both together at exactly the same time Ho...

Страница 13: ...red wiring systems The cradle for the power supply supplied should be mounted alongside the hub The PSM130 plugs into a suitable AC mains socket and should be mounted in its wall mounted cradle The DC...

Страница 14: ...t inputs of the SIM module with the window emitters supplied plugged directly into the IR TX sockets on the IRM module and attached to the infra red receiving window of the hi fi system or music sourc...

Страница 15: ...Using a patch cord assuming that a patch panel has been used connect the system input from the system room to the RJ 45 socket on the hub marked REMOTE AUDIO IN This connection is not required if the...

Страница 16: ...doesn t happen try again The speaker system is now in setup mode Using the VOL and VOL keys on the remote adjust the volume to a level that you want the system to turn ON at This will be the turn ON...

Страница 17: ...imultaneously both together at exactly the same time Hold briefly until you see the status LEDs flash The LEDs will flash to show you the new sequence which is Blue Green Blue Green Red Mode 2 Local e...

Страница 18: ...e address unless you need to for independent sub zone operation The keypad must have its address set in the following way With the keypad connected to the speaker and the red standby LED ON depress th...

Страница 19: ...rking this probably indicates a break or fault in the wiring between this zone and the audio distribution hub If no zones are working this probably indicates a fault in the wiring between the audio di...

Страница 20: ...ing Some zones sound too loud when first switched on The start up volume is configurable for each active speaker Adjust the start up volume of the zone as described in Setting bass treble and minimum...

Страница 21: ...the remote or O key on the keypad to toggle to the next input The green local LED will illuminate on the speaker and also on the keypad if fitted Note The volume will ramp down and the speaker will s...

Страница 22: ...ON by pressing the O key on the keypad or remote Controlling of the audio source in the sub zone is done using either the original equipment remote or else a learning remote containing the source code...

Отзывы: