SerialGate User Guide
93
Verification
It verifies each interface HW of a device server.
In order to select System, press ‘
ESC’
on the panel until ‘
Main Menu’
comes up, and if
‘Main Manu’
is
displayed, press
‘<<
’ or
‘>>
’ until you see ‘
Verification’.
Then, press ‘
Enter’
to change the details.
At anytime ‘
ESC’
is selected, it moves to the top menu.
(*) When a user performs this test, all the program running in a device server stops. So, a user must
restart the device server after the test.
Menu
Option Default
Description
RS232(Loopback)
Cancel Yes Cancel
<<, >> : Select option.
Enter : If Cancel selected, go to the next menu.
If Yes selected, that action is performed.
RS232(Signal)
RS422(Loopback)
RS485(Loopback)
Testing WAN Port
Testing LAN Port
Testing MMC
Testing Reset
Testing Console
Testing RTC
RS232 (Loopback)
Change all the serial ports of a device server to RS-232, and conduct a Loopback test.
RS-232 Loopback connector must be connected to all the serial ports for the test.
If a user selects ‘yes’ option, it starts Loopback test and prints out the result on L
CD.
T e s t I n g ( R S 2 3 2 )
O O O O O O O O O O O O O O O O
If there is nothing wrong, it displays ‘O’ or ‘X’ otherwise.